Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
206
Operation and Maintenance
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
6. 3. 5
Power supply module
The UPS-12V module is connected with the mainboard via two 6-pin connectors.
Information on installation and removal can be found in
.
6. 3. 6
Mainboard
If the mainboard or one of the system cards is defective or permanently faulty, the
entire basic system will have to be replaced, complete with system cards and metal
housing.
Replacing the mainboard
1.
If still possible, save the configuration data using AIMS (
Tools
→
Backup
).
2.
3.
Remove the PBX cover.
4.
Remove the expansion cards and UPS module. For details of the procedure for
removing expansion cards, see
"Replacing a defective expansion card",
.
5.
If a backup of the configuration data is not available, the data can still be saved
by switching the Flash card to the new mainboard (see
).
6.
Replace the EIM card of the defective mainboard and the new mainboard. See
for the procedure.
7.
Dismantle all the connected cables in such a way that the new basic system can
be identically reconnected.
8.
The mainboard is not dismantled but replaced complete with metal housing.
Depending on the installation (wall-mounting / cabinet mounting) the housing
with the mainboard may also have to be dismantled and the housing cover
screwed back on.
9.
The new basic system can now be reassembled and fitted in the reverse se-
quence.
10.
If the configuration data was not transferred when changing the Flash card, ini-