Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
214
Operation and Maintenance
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
– To enable the operator console groups of an Office 1560/1560IP or
the workgroups of an Office 1600/1600IP, as of I6.6 you now require
the OIP Call Centre Licence and a CTI Professional Licence for each
client. These licences are generated automatically with the upgrade
to I6.6 (version transfer).
– The initialization values for the internal digit barring 1 and 5 have
changed: *9, #9 and *#9 in the barring list have been replaced by
*57 and *58). Entry *90 in the enabled list has been deleted. These
values are not automatically re-used during a version transfer; they
need to be adapted manually.
6. 4. 5
System Upgrade from I6.6 to I7.x (x<5)
Upgrading a 2025/2045 or 2065 system from I6.6 to I7.x (x<5) requires new system
software. The system upgrade can be carried out on site or remotely with a version
transfer:
1.
Initiate the upload process as described in the paragraph
. Select
"Start Now"
as the activation time.
2.
Once the upload is completed, the PBX resets and is then ready to operate again
with the new system software and the usual system configuration.
Note:
AIMS I7 is required in order to update the I7 system. Once AIMS 7 has
been installed and started, the switch in PBX generation from I6.6 to I7
has to be carried out on the corresponding system. Note: If the PBX
generation is incorrect, AIMS 7 cannot access the PBX after the soft-
ware upgrade and generates the corresponding error message.
6. 4. 6
System Upgrade from I6.6 or I7.x (x<5) to I7.5
Upgrading a 2025/2045 or 2065 system from I6.6 or I7.x (x<5) to I7.5 requires new
system software and additional RAM and flash memory. An "Update-Set 7.5" con-
sisting of a RAM card and a Flash card is provided for this purpose. The flash card is
pre-loaded with an I7.1+ software package which is compatible with 7.1 and sim-
plifies the upgrade. The same update set is used for the systems 2025/2045 and
2065.
1.
Updating OIP to 7.5 (where applicable).
2.
Installing and starting AIMS 7.5 (backward compatible to I6.6).