Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
Operation and Maintenance
249
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
Errors that concern partial functions overwrite the standard output of the main-
board's 7-segment display for 10 seconds. Errors that lead to a restart are displayed
permanently.
Error messages are characterized by the letter E (= error), followed by a three-digit
error code. The individual digits appear one after the other on the single-digit sta-
tus display of the mainboard (7-segment display with decimal point).
In the example below (system error message 022) each individual digit appears for
0.5 seconds. The hyphen marks the start of
the 3-digit error message
E.0.2.2.-.E.0.2.2. - .......
6. 5. 6. 2
Error coding
The first digit indicates where the error has occurred; the two-digit code that fol-
lows classifies the error.
Tab. 118 Overview of error localization
The following overview of error messages contains the error code and a column
with the description of the error.
Tab. 119 Error message during software version transfer (version transfer configuration data organiza-
tion OIM)
Note:
If error codes 402 to 405 occur, the system will halt the startup. Proceed-
ing with the startup results in a system initialization.
Code
Description
E-4xx
Error during software version transfer
E-5xx
Self-test error
E-6xx
Data transmission error
Identification
Error description
Error handling
404
Version transfer not possible: Country and / or sales
channel on the PBX (EIM card) does not match
information in the configuration data on the Flash
(e.g. country code in Flash memory is CH and in the
software it is D)
• Using AIMS set a different EIM card
and / or distribution channel.
405
Version transfer not possible:
Software release unknown.
• Load new software onto main-
board