Power Supplies
Tab. 132 Technical data, UPS-12V module
Tab. 133 Technical data, Auxiliary Terminal Power Supply (ATPS)
2025/2045 basic system
2065 basic system
Input voltage
12 VDC (10 V…15 V)
Input current
max. 8.2 A with 12 V
max. 15.8 A with 12 V
Fuse cartridge
20 A (Wickmann FK1 20 A)
Floating charging voltage
13.5 V ± 2%
Charge current limiting
1.0 A or 2.0 A (adjustable)
Battery cable
4 mm2, max. 7 m
4 mm2, max. 3.5 m
Weight
520 g
Dimensions
278 x 98 x 40 mm
Auxiliary Terminal Power Supply (ATPS)
Input voltage (mains)
90 - 254 V, 47 - 63 Hz
Input current
max. 2 A with 230 V
Output voltage
40 +/-1 V
Max. power output
250 W
Cables supplied
DC connecting cable to the PBX (1.2 m, permanently fitted)
230 V ATPS mains cord to the PBX, (2 m, pluggable)
Weight
1630 g