Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
Installation
139
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
[1]
Direct connection
[2]
Indirect connection; connector for prefabricated 16-wire connecting cable
= Pin 1
Fig. 77
Control inputs on the OI-2DOOR special card
Tab. 67
Line assignment for control inputs
If required, signalling LEDs without series resistor can be connected in series with
the external switches.
4. 7. 5. 3
Freely connectable relay
The freely connectable relay can be used to control heating, alarm or outside light-
ing systems (possibly via external relay for 230 VAC).
Interface
Connection
Pin
Control input 2
GNDC
1
ME2
2
Control input 1
GNDC
3
ME1
4
Door
intercom x.1
Interface
switch group 1
1
2
3
Freely connectable
relays
Door
intercom x.2
[1]
[2]
1
2
15
16
View A
A
GNDC
ME 3
ME 2
10K
GNDC
GNDC
ME 1
10K
Switch 2
Switch 1
haz1157aaenc0
Pot 1
Pot 2
-40V
(internal)
10K