Installation
This Chapter tells you how to install Ascotel® IntelliGate® 2025/2045/2065 and the con-
ditions to be observed. It also includes the mounting into a 19” rack, the correct way to
connect the earthing, and the power supply. Other topics in this chapter are equipping
the basic system with expansion cards and the network-side and terminal-side wiring
of the interfaces.
4. 1
Mounting the PBX
The PBX can be both wall-mounted or installed vertically inside a 19" system cabi-
net. A special rack version is available for horizontal mounting in a 19" system cabi-
net (see
"Rack version Ascotel® IntelliGate®", page 61
).
4. 1. 1
Location requirement
The following location requirements must be observed when positioning the PBX.
Hazard
Failure to observe the location requirements can cause the system to
overheat, damaging electrical components and/or the surrounding area..
Tab. 24
Location requirements for basic systems
Location requirement
Heat radiation
• Do not position the system in direct sunlight or near heating sources
EMC
• Do not position the system in strong electromagnetic fields of radiation (e. g.
near x-ray equipment, welding equipment or similar).
Heat dissipation
• Observe the clearance requirements with the system (see
)
• Provide ventilation slots of approx. 600 cm2 each at the top and bottom of
built-in cabinets
Environment
• Room temperature 5...35 °C
• Relative humidity 30…80%, non-condensing