Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
60
Installation
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
Fig. 16
Accessories for installation set and installation of the PBX in a 19" system cabinet
Installing the PBX into a 19" system cabinet
1.
Step A: 8 Fit 8 cage nuts [7] (see
). The space between the rails should be
8 height modules on the inside (or 12 height modules on the outside).
2.
Step B: Premount upper plug-in unit with parts 1, 3, 4, 6 (see
3.
Step C: Premount lower plug-in unit with parts 2, 3, 4, 6 (see
4.
Step D: Slide the mounted plug-in units into the system cabinet.
5.
Step E: Use 8 screws [5] to screw the plug-in units to the system cabinet (see
6.
Step F: 2 Loosely screw screws [6] approx. 4 mm into the upper back rails [1] (see
For 2025/2045 system use an internal thread, for 2065 system an external thread.
7.
Step D: Suspend the PBX into the loose screws and secure to the lower back rail
[2] with 2 screws [6].
F
G
haz1253aaxxa0