Maintenance
To ensure the optimum effi ciency, perform visual checks and maintenance of
ASIN AQUA Oxygen on a regular basis.
Pump Hose Replacement
To prevent the pump from failing, it is recommended to replace the hose
#12073 every 24 months.
In doing so, proceed as follows:
•
Switch off ASIN AQUA Oxygen.
•
Turn the pump cover cassette anticlockwise and take it out of ASIN AQUA
Oxygen.
•
Release both hose ends and take it out of the cassette.
•
Lubricate the new hose with the supplied special grease.
•
Insert the lubricated hose into the cassette.
•
Place the cover cassette back on ASIN AQUA Oxygen and turn it clockwise
to lock it.
•
Use new nuts, which are part of the replacement hose set, for connection of
the PE tube.
Injection Valve Maintenance
On a regular basis, check throughput of the injection valves, rubber band
integrity, remove scale.
In case of private pools, replace injection valve rubber bands every 2 years. In
case of public pools, replace #12005 every year.
pH Probe Maintenance
Take the pH probe out of ASIN AQUA Oxygen housing and clean it from
impurities.
Follow the instructions attached to the used probe.
#12073 Replacement hose
for the pump PP 60
#12005 Injection valve
#13087 Replacement rubber band
for injection valve