Pool Water Connection to the
probes
The pool water to be measured must be connected to ASIN AQUA Salt.
Speedfi t connection
Aseko provides the unique Speedfi t connecting fi tting for measured water
connection. To connect the interconnecting tube, push it into the Speedfi t
connector and then lock it by pulling back. To disconnect the interconnecting
tube, push and hold a circular collet and pull the interconnecting tube out.
Water valve fi tting
Place the water valve fi tting to the T-joint, blinded by glue head D50-1/4” #12134.
Water valve
fi tting
G1/4” thread
6.2x4 hose
CONNECTION
LOCKING
DISCONNECTION
Water valve fi tting
Glue head D50-1/4”
#12134
T-joint
6.2x4 hose
90°
Pull out
When the electrode is in bypass
is installed (which we recommend), either
the sample water extraction or the sample water return must also be installed
in the bypass.
This ensures that the electrode only receives electricity when when there is
water fl ow.