Aseptico warrants this product against defects in material or workmanship for a period of

two (2) years, from date of original invoice.  Some handpieces are warranted for one year

under the same conditions.  Other handpieces and expendable components, such as air

turbines and light bulbs, are covered by shorter warranty periods, or have no warranty.

Aseptico's sole obligation under product warranty is (at its sole option and discretion) to

repair or replace any defective component or product in part or whole.  Aseptico shall be

the sole arbiter of such action.

In the event of alleged defect under warranty, the purchaser is to notify Aseptico's

Customer Service Department promptly.  Customer Service will provide instructions,

usually directing that the product be returned for service.  Shipment to Aseptico and the

cost thereof is always the responsibility of the purchaser.

Accidental misuse, inappropriate installation, or failure to perform directed maintenance

voids the warranty. Deliberately defacing, modifying, or removing the serial number voids

the warranty.

Aseptico does not assume, under this warranty, any risks or liabilities arising from the

clinical use of its products, whether or not such use involves coincidental utilization of

products manufactured by others.

WARRANTY

Summary of Contents for 6520-01-600-8241

Page 1: ...ALU 40LED CF Portable Dental Lamp NSN 6520 01 600 8241 OPERATION MAINTENANCE MANUAL ...

Page 2: ... 3157 Toll Free 800 426 5913 www aseptico com info aseptico com INFORMATION CONCERNING THE ACCURACY AND PRECISION OF THIS PRODUCT MAY BE OBTAINED UPON REQUEST BY CONTACTING ASEPTICO AT THE ADDRESS SHOWN ON THIS PAGE To prevent injury to people and damage to property please heed relevant warnings and remarks They are marked as follows WARNING Serious injury or death may result if ignored CAUTION Da...

Page 3: ...ions provided in this manual to receive the best and longest service from your Aseptico equipment Separate manuals may be provided to cover the operation and maintenance of other accessories for your unit PACKAGE CONTENTS Portable Dental Lamp Assembly PN 120369 01 Color Filter PN 461974 For use with light activated composites Two 0 160A Spare Fuses PN 830046 DC Battery Power Clip Assembly PN AA 40...

Page 4: ...ded for operation in the presence of flammable anesthetics or gases CAUTION Connect AC power supply mains cable to a properly grounded outlet only CAUTION The ALU 40LED CF Lamp is sensitive to shock and may be damaged if dropped or impacted against a hard surface WARNING Do not disassemble or alter the Lamp s LED Boom Arm or Power Supply subassemblies CAUTION It is recommended to always have the p...

Page 5: ...desired height Tighten the handgrip to secure post in place Loosen the boom adjustment handle and extend boom to desired length and or pivot the lamp head to the desired operating position Tighten handle to secure the boom in place SETTING UP THE UNIT Fig 1 System Components POWER SUPPLY TELESCOPING CENTER POST FLEXIBLE GOOSENECK LAMP HEAD w ADJUSTABLE CONTROLS PEDESTAL PEDESTAL ADJUSMENT KNOB CEN...

Page 6: ...ug adapters for the specific country of usage may need to be purchased separately DC Power If the power source is 12VDC or 24VDC use the DC Battery Clip or Power Plug Adapter Assemblies to connect to the DC source see Figure 3 Insert the Assemblies Power Plugs into the DC Power Jack located on the bottom of the power supply housing see Figure 2 page 3 NOTE When attaching the DC Battery Clips Figur...

Page 7: ...ariable brightness control When viewed from the rear of the Lamp Head rotate Ring clockwise to increase lamp intensity or counter clockwise to decrease intensity The intensity adjustment range is from 0 to 100 NOTE The total adjustment range of the Intensity Ring covers approximately 90 of rotation do not OPERATION attempt to force the Ring past the stops at each end of this range b LED Aperture A...

Page 8: ...outer shelf on the Front Housing see Figure 7 e Attach Lens to Housing with the three Fasteners from Step 1c above f Replace Lens Cover 2 LENS ADJUSTMENT Follow these steps to adjust the position of the Lens so that it emits the sharpest beam refer to Figures 6 7 a Position Lamp Head approximately 28 71 cm away from a flat test surface Turn Lamp On and observe sharpness of projected light beam see...

Page 9: ...f dish soap to a lint free lens tissue and gently wipe Lens Clean the Lens Cover using the same method Reinstall Fresnel Lens and Lens Cover onto Lamp Head b Metal Components The metal exterior may be cleaned by wiping with a soft cloth moistened with mild detergent or disinfecting solution such as isopropal alcohol c Gooseneck Electrical Cords Turn Lamp power Off Wipe down the gooseneck and elect...

Page 10: ...8 ALU 40LED CF PARTS DIAGRAM Figure 9 Lamp Stand Boom ALU 40LED CF LAMP HEAD Refer to Figure 11 page 12 2 3 4 5 6 7 9 11 10 8 12 13 5 11 1 ...

Page 11: ...3 1 SET SCREW CONE PT HEX SOC M6 X 8MM BLK 510731 1 HEAT SHRINK 1 8 BLK 870118 1 HEAT SHRINK 1 4 BLK 870120 2 5 HOLE PLUG NYLON 1 2 IN BLACK 510202 1 M S STNLS PHDPHL 10 24 X 5 8 THRD CUTTING 510732 1 END CAP MODIFIED BOOM ALU 40 461959 1 CABLE COILED 2 CONDUCTOR ALU 40LED CF 870319 1 HANDLE CLAMP LEVR M8X1 0 FEM THRD BLK 850076 1 CLAMP BOOM ALU 40 LED 730646 1 1 2 3 4 5 6 7 8 9 10 11 12 13 Cont d...

Page 12: ...10 ALU 40LED CF PARTS DIAGRAM Figure 10 Lamp Stand Power Supply 15 16 20 23 24 41 19 18 37 21 16 33 36 28 35 34 26 27 28 23 25 32 32 29 30 40 38 39 42 17 22 ...

Page 13: ... 1 WIRE PVC 22 GRN YEL 54 870260 0 21 CONN JACK DC POWER PCB MOUNT 860333 1 FUSE 5 X 20 SLO BLO 0 160 AMP 830046 2 FUSE DRAWER 2 POLE 840060 1 POWER INLET FUSED SWITCHED 840059 1 POWER SUPLY 12VDC 0 83A INPUT 85 264 VAC 840112 1 NUT NYLON 4 40 510554 4 WASHER FLAT NYLON 120IDX 250 ODX 0 510127 4 SPACER NYLON 1 4 RND X 7 16 L 6 510267 4 BASE POWER SUPPLY ALU 40LED CF 461944 1 STAND ALU 27 29 AKG BL...

Page 14: ...12 Figure 11 Lamp Head 2 4 5 8 9 18 17 6 3 6 7 10 11 13 19 16 15 1 21 12 20 14 ...

Page 15: ...488 1 WASHER SHIM 43 OD X 115 ID X 01 STNLS 510726 1 APERTURE ADJUST RING ALU 40LED CF 461931 1 RES 100K TRIM POT 350V 1 2W 810430 1 WIRE 24 TEFLON 41 40 TINNED COPPER WHT 870314 2 WIRE 24 TEFLON 41 40 TINNED COPPER BLK 870320 2 PCB ASSY LAMP HEAD ALU 40LED CF 330578 1 FTN UNIVERSAL JOINT M10 1 0 MALE THRDS 730643 1 WASHER 6 NYL 140 ID X 312 OD X 032 THK 510573 1 REAR HOUSING PLATE ALU 40LED CF 46...

Page 16: ...y up Replace fuses 0 160 Amp 5 x 20mm 250V slo blow Check plug and electrical source Turn intensity up Clean Lens Cover and or Fresnel Lens Note Before cleaning turn power to Lamp Off Check plug and electrical source LED Assembly might be damaged Return entire Lamp Assembly to Aseptico for repairs Replace both fuses 0 160 Amp 5 x 20mm 250V slo blow ...

Page 17: ...ter 5 72 cm to 11 74 cm Adjustable 27 56 in 70 cm focal length Beam Characteristics Color temperature 6 500 Kelvin Light Output 1 500 ft c 24 Typ 16 145 lux 61 cm Typ Light Distribution 7 different aperture sizes Nominal Working Distances 16 40 6 cm w large aperture or 36 91 4 cm w small aperture Light Source LED Emitter 1013 3 hPa 697 hPa 10 90 10 C 50 F 45 C 113 F OPERATING TEMPERATURE 20 C 4 F ...

Page 18: ...ntion consult accompanying documents Type B Equipment Do Not Throw Into Trash Class II Equipment Manufacturer Authorized European Representative Protective Earth Ground Temperature Limitation Atmospheric Pressure Limitation Humidity Limitation Fuse Rating 0 160A 2X ...

Page 19: ...iter of such action In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service will provide instructions usually directing that the product be returned for service Shipment to Aseptico and the cost thereof is always the responsibility of the purchaser Accidental misuse inappropriate installation or failure to perform di...

Page 20: ...P N 420914 Rev G ECO 14684 03 2019 PRINTED IN THE USA P O Box 1548 Woodinville WA 98072 8333 216th Street S E Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com ...