2.

7.

Alternating current

Protective earth (ground)

Earth (ground)

Dangerous Voltage

Attention, consult 
accompanying documents

SYMBOL DEFINITIONS:

Type B Equipment

IMPORTANT:

If the electric power is interrupted by a
power failure, unplugging the power
cord, or by any other means, while the
compressor is running, turn the
AUTO/OFF lever to 'OFF' and then back
to 'AUTO' to relieve back pressure and
restart the compressor.  If the power is
interrupted, follow these steps
immediately to prevent any motor
damage. 

OPERATION

:

After unpacking the compressor, open the
case and locate the remote power cord
and air intake filter inside (see Figure 1).
Screw the air intake filter into the 1/4" NPT
hole in the top of the compressor head
assembly.  Plug the power cord into the
receptacle on the outside end of the case
(see Figure 2) and then into a grounded
power outlet.  The AA-74 compressor is
operated by an AUTO/OFF lever on the
top side of the pressure switch inside the
compressor case.  By turning the lever to
the 'AUTO' position, the compressor will
start and stop automatically to maintain
pressure.  The pressure switch is factory
adjusted to properly start and stop.  To turn
the compressor off, turn the lever to the
'OFF' position.

1. After plugging the compressor in and

turning on, close the lid for operation.  Let
the compressor run until it stops, indicating
full pressure.

2. Locate the air output 1/4" quick disconnect

and pressure gauge on the end of the
compressor case (see Figure 2).  Connect
a 1/4" male coupling from your equipment
to the air output fitting.  The pressure
gauge indicates pressure in the air storage
tanks and gives a visual indication that the
compressor is maintaining pressure
properly.

3. The AA-74 compressor will cycle on and

off as air is consumed during use.  This is
normal for operation.  Turn compressor off
if not used for extended periods of time.

Summary of Contents for AA-74

Page 1: ...OPERATION AND MAINTENANCE INSTRUCTION MANUAL AA 74 AIRPAC COMPRESSOR 120 VOLT ...

Page 2: ......

Page 3: ...and includes an air storage tank and an automatic pressure switch control Congratulations This system is engineered to provide many years of reliable service Please read the instructions provided in this manual to receive the best and longest service from your Aseptico equipment Separate manuals may be provided to cover the operation and maintenance of other accessories for your unit PACKAGE CONTE...

Page 4: ......

Page 5: ...ILTER AIR INTAKE FILTYER PRESSURE SWITCH PRESSURE GAUGE AIR OUTPUT Figure 1 Case Contents Figure 2 Case Top View PRESSURE GAUGE AIR OUTPUT QUICK DISCONNECT PRESSURE SWITCH AIR STORAGE TANKS DRAIN FITTING AIR INTAKE FILTER AC POWER RECEPTACLE AIR INTAKE FILTER ...

Page 6: ......

Page 7: ... equipment 3 If compressor is run for extended periods of time open case for more efficient cooling 4 All compressors generate heat even under normal operating conditions To avoid serious burns never touch the compressor during or immediately after operation 5 When unit is not in use wrap cord and store inside compressor Do not abuse cord 6 Servicing should always be performed by an Authorized Ser...

Page 8: ......

Page 9: ...7 Alternating current Protective earth ground Earth ground Dangerous Voltage Attention consult accompanying documents SYMBOL DEFINITIONS Type B Equipment ...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: