ADC-01
COLLAPSING THE CHAIR
WARNING:
Never force the chair into the collapsed
position. Forcing the chair down without releasing the
backrest adjustment lever may bend the adjustment
assembly and will void the warranty.
1.
Fold toe and then leg panels onto seat as it was originally
stored.
2.
Pull arm slings out of the holes in the chair frame.
3.
Put your toe onto one of the front chair legs and lift up slightly
on the seat, then remove height adjustment pins. While
supporting chair weight, let the chair fold down toward the
floor.
4.
As the chair folds down, release the backrest adjustment lever
until the chair collapses completely. Rotate the chair up onto
one side and insert the leg adjustment pins into their storage
pouch underneath the chair seat.
5.
Fold the arm slings and headrest onto the chair and place
folded chair into carrying case.
CLEANING
Although bleach, when diluted to <10% and wiped off immediately
could be used, it is not recommended. The use of barrier covers
and mild cleaning solutions is recommended as the primary asep-
sis approach on chair and stool upholstery instead of relying on
chemicals. The use of barriers greatly extends the life of chair and
stool upholstery and can be replaced between patients.
WARRANTY
Aseptico Inc. warrants this product against defects in material or
workmanship for a period of two (2) years, from date of original
invoice. Some handpieces are warranted for one year under the
same conditions. Other handpieces and expendable components,
such as air turbines and light bulbs, are covered by shorter warran-
ty periods, or have no warranty. Aseptico’s sole obligation under
product warranty is (at its sole option and discretion) to repair or
replace any defective component or product in part or whole.
Aseptico Inc. shall be the sole arbiter of such action.
In the event of alleged defect under warranty, the purchaser is
to notify Aseptico’s Customer Service Department promptly.
Customer Service will provide instructions, usually directing that
the product be returned for service. Shipment to Aseptico and the
cost thereof is always the responsibility of the purchaser.
Accidental misuse, inappropriate installation, or failure to perform
directed maintenance voids the warranty. Deliberately defacing,
modifying, or removing the serial number voids the warranty.
Aseptico Inc. does not assume, under this warranty, any risks or
liabilities arising from the clinical use of its products, whether or
not such use involves coincidental utilization of products manufac-
tured by others.