CLEANING:
Surface Disinfecting
- Any external surfaces of
the ADU-08SX unit that are contacted during use
should be carefully wiped down with a disinfectant
between patients. The entire unit should be
thoroughly cleaned at least once a day.
Vacuum System
- After each patient, the air
vacuum system should be thoroughly rinsed by
evacuating clean water through the hose end
followed by air to clear all water from the tubes.
The entire system should be cleaned and
disinfected each time it is emptied.
CAUTION
: Use
only NON-foaming cleansers in the vaccum lines.
Syringe tips should be changed between patients,
and used tips thoroughly cleaned and autoclaved
before reuse.
Air/Water Filter
- The ADU-
08SX unit contains a built-in
air line filter. It removes
unwanted moisture, oil, dirt,
chips, and other contaminates
that may enter the air supply
line. To ensure clean dry air
to your unit, the filter bowl
must be drained regularly. If a
significant amount of water can be seen
through the sight glass on the moisture
collection bowl, the filter should be drained.
To drain, extend the drain line outside the
unit and unscrew the drain valve. Allow all
moisture to drain out, then retighten drain
valve.
Water Lines
- Disinfect the water lines
weekly. Prepare a 1:10 bleach solution (1
part household bleach to 10 parts water).
Remove water reservoir and discard
residual water. Replace empty water
supply tank and air purge all waterlines. Fill
water supply tank with bleach solution. Run
bleach solution through all lines. Allow
bleach solution to stand in lines for 10
minutes. Remove water supply tank and
discard bleach. Flush water supply tank
and all lines thoroughly with clean water.
Air purge and leave lines dry until next
clinical use.