2.
SAFETY PRECAUTIONS:
Aseptico accepts no liability for direct or consequential injury or damage resulting from improper use, arising in
particular through the non-observance of the operating instructions, or improper preparation and maintenance.
WARNING:
Clean, disinfect, and sterilize new or repaired handpieces and instruments before first use and between
each patient use. Only use sterilized handpieces and instruments during treatment. Non-sterilized
handpieces and instruments may cause bacterial or viral infections. Always sterilize handpieces and
instruments after operation.
CAUTION:
Always examine unit components for damage before commencing treatment. Damaged components
must not be used and must be replaced.
WARNING:
Use for intended purposes only. Failure to observe the operating instructions may result in the patient or
user suffering serious injury or the product being damaged, possibly beyond repair. Before using this
product, make sure that you have studied and understood the operating instructions.
WARNING:
Do not install where there is a risk of an explosion. The system is not intended for operation in the
presence of flammable anesthetics or gases.
WARNING:
Always operate a high-speed handpiece with water coolant. Operating a high-speed handpiece without
water coolant can cause thermal injury to the patient.
CAUTION:
The lens for the electric motor LED is soft and can be damaged. If the lens needs to be cleaned, use a
lint-free swab and isopropyl alcohol - do not use other solvents as they might adversely react with the
LED assembly.
CAUTION:
The system’s electric motor is not recommended for use with endodontic files that have torque limit
requirements less than 100 g-cm.
WARNING:
Do not use this device for dental implant procedures.
CAUTION:
Do not run saline solutions through the water system -- saline will rust the water filters.
WARNING:
For use by qualified and trained personnel only.
WARNING:
CONTRAINDICATION: Ultrasonic oscillations emitted by the optional Ultrasonic Scaler may prevent the
proper function of cardiac pacemakers. Therefore, Aseptico recommends that patients with a cardiac
pacemaker should not be treated with the Ultrasonic Scaler component of the AEU-525S System.
WARNING:
The optional Ultrasonic Scaler instrument tips oscillate at high frequency and can fracture during
operation. To help prevent the tips from fracturing and possibly injuring the the patient, always follow the
scaler manufacturer's operating instructions and recommended ultrasonic power settings.
WARNING:
Do not use the optional Ultrasonic Scaler dry. If used dry, the Instrument Tip will heat immediately. This
may cause thermal injury to the tooth. Ensure that adequate liquid coolant is always available.
CAUTION:
Never use the optional Ultrasonic Scaler on metal or porcelain restorations. The high frequency
ultrasonic oscillations may loosen the restoration.
CAUTION:
Operating the system without using the High or Low Volume Evacuation can cause the compressor
motor to cycle on/off, possibly affecting other electrically powered equipment sharing the same circuit.
CAUTION:
Dispose of electronic waste and waste containing amalgam in accordance with local regulations.
WARNING:
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could
result in improper operation. If such use is necessary, this equipment and the other equipment should be
observed to verify that they are operating normally.
WARNING:
Use of accessories, transducers and cables other than those specified or provided by the manufacturer
of this equipment could result in increased electromagnetic emissions or decreased electromagnetic
immunity of this equipment and result in improper operation.
WARNING:
Portable RF communications equipment (including peripherals such as antenna cables and external
antennas) should be used no closer than 30 cm (12 inches) to any part of the unit, including cables
specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
WARNING:
Do not stare into the handmotor led! The light from the hand motor LED may cause eye injury.
WARNING:
Do not stare into the scaler leds! The light from the scaler LEDs may cause eye injury.