MAINTENANCE & CLEANING:
H
ANDPIECES
- Thorough cleaning and lubrication
of handpieces after each use and before sterilization
is very important to ensure proper operation and
service life of the handpiece. Follow the instructions
provided with the handpiece for complete
maintenance instructions.
MOTOR
-
IMPORTANT!
Protect
motor from excess oil draining from
handpiece. After lubricating and
before autoclaving, stand handpiece
by its base on a paper towel and
allow excess oil to drain (see Figure
16).
CONSOLE
- The exterior of the console may be
cleaned by wiping with a soft cloth moistened with
a mild detergent or a 1:10 bleach solution (1 part
household bleach to 10 parts water).
IMPORTANT:
Use of other cleaning or disinfecting solutions may
damage the console and may void the warranty.
SILICONE WATER LINES
- The silicone water
lines used for the pump are fully autoclavable:
Pre-Cleaning:
Before sterilization, run clean water
through the tubing for 30 seconds to expel any
stagnant water.
NOTE:
Do not use disinfectants on
the tubing set. Bacteria and viruses will be
neutralized during sterilization.
Sterilization:
Sterilize tubing at 132º C (270º F) for
10 minutes.
FOOT CONTROL
- The exterior of the foot control
may be cleaned by wiping with a soft cloth
moistened with mild detergent or disinfecting
solution. When cleaning, remove handle from foot
control and wipe clean with disinfectant, then
reinstall handle.
• Do not attempt to disassemble the motor or motor
connector.
• Do not oil or lubricate the motor.
• Do not attach a handpiece to the motor while the
motor is running.
• Do not bend motor cord sharply.
• The motor is sensitive to shock. Do not drop or
impact motor against a hard surface.
WARNING
Failure to comply with any of the above instructions
may void your warranty.
Fig.16
SPECIFICATIONS:
Console Dimensions: 9.98”W x 9.42”L x 5.10”H
(25.3 cm x 23.9 cm x 12.9 cm)
Console Weight:
7.3 lbs (3.3kg)
Power:
100-240V
1.1 - 0.5 A
50-60 HZ
Fuses:
1.6A, 250V, Slo Blow Type
Duty Cycle:
16.7%
NOTE: The appliance inlet is the
mains disconnect means.
Environmental Conditions:
Operating Temperature 10 to 28°C (50 to 82.4°F)
Transportation & Storage Temperature -20 to 60°C
(-4 to 140°F)
Relative Humidity 10 to 90% non-condensing
Altitude 0 to 3048 meters (0 to 10,000 feet)
10°C
(50°F)
28°C
(82.4°F)
OPERATING
TEMPERATURE
-20°C
(-4°F)
60°C
(140°F)
TRANSPORT &
STORAGE
TEMPERATURE
1013.3
hPa
697
hPa
10%
90%
Summary of Contents for AEU-7000E