To prevent injury to people and damage to
property, please heed relevant warnings
and remarks. They are marked as follows:

WARNING:

Serious injury or death may
result if ignored.

CAUTION:  

Damage to property or the
environment may result if
ignored.

NOTE:

Important additional

information and hints.

TABLE OF CONTENTS:

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . .1

Package Contents  . . . . . . . . . . . . . . . . . . . .1

Setting Up the Unit  . . . . . . . . . . . . . . . . . . .2

Operation Functions  . . . . . . . . . . . . . . . . . .4

Speed Ranges . . . . . . . . . . . . . . . . . . . . . . .4

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Sterilization and Maintenance  . . . . . . . . . . .6

Troubleshooting . . . . . . . . . . . . . . . . . . . . . .7

Symbol Definitions . . . . . . . . . . . . . . . . . . . .7

Warranty  . . . . . . . . . . . . . . . . . . .Back Cover

SPECIFICATIONS:

Console Size:      8.125” x 7.25” x 3.25”

(20.6375 cm x 18.415 cm

x 8.255 cm)

Console Weight:  3.75 lbs (1.6875 kg)

Power Source:    110V/120V 60Hz or

220V/250V 50Hz

Fuses:                1A/110V

0.5A/220V
Slo Blo Type

CLASSIFICATIONS:

• Internally Powered Equipment  

• Type B Equipment

• Ordinary Equipment - degree of protection

against ingress of water

• Not suitable for use in the presence of a flam-

mable anesthetic mixture with air or with oxy-
gen or nitrous oxide.

P.O. Box 1548 • Woodinville, WA 98072

8333 216

th

Street S.E. • Woodinville, WA 98072

(425) 487-3157 • (800) 426-5913

www.aseptico.com • info@aseptico.com

WARNING: This device has been tested and found
to comply with the emissions requirements of IEC
60601-1-2:2001-09.  These requirements provide
reasonable protection against harmful electromag-
netic interference in a typical medical installation.
However, high levels of radio-frequency (RF) emis-
sions from electrical devices, such as cellular
phones, may disrupt the performance of this device.
To mitigate disruptive electromagnetic interference,
position this device away from RF transmitters and
other sources of electromagnetic energy.

Summary of Contents for AEU-707A

Page 1: ...AEU 707A AEU 707AV2 Implant Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL ...

Page 2: ...LASSIFICATIONS Internally Powered Equipment Type B Equipment Ordinary Equipment degree of protection against ingress of water Not suitable for use in the presence of a flam mable anesthetic mixture with air or with oxy gen or nitrous oxide P O Box 1548 Woodinville WA 98072 8333 216th Street S E Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com WARNING This device ha...

Page 3: ...iable service Please read the instructions provided in this manual to receive the best and longest service from your Aseptico equipment Separate manuals may be provided to cover the operation and maintenance of hand held pieces or other accessories for your unit PACKAGE CONTENTS Electronic Control Console AE 4B 30 Autoclavable Brushless Micro Motor Autoclavable Motor Holder AE 7P On Off Foot Contr...

Page 4: ... is shipped with the console 2 Attach the remote power cord to the back of the console and plug into a grounded elec trical receptacle 3 Connect the motor to the receptacle on the lower front panel of the console 4 Attach the appropriate E Type handpiece to the motor as shown in Figure 3 5 Insert bag hanger rod into holder on the top of the unit Thread into place 6 Attach the supplied foot control...

Page 5: ...ound the rollers with slight tension and insert into bottom slot on the pump block d While maintaining tension on the tubing check that tubing is centered on the rollers and is completely tucked into slots on pump block Then replace clear pump cover by sliding into position from front to back and securing with the thumbscrew e Route the remaining length of tubing to the handpiece and connect to th...

Page 6: ...Up arrow to increase speed and the Down arrow to decrease speed A visual display shows actual RPM Ratio selector must match exactly the ratio of the hand piece being used for complete accura cy 5 Forward Reverse Determines the rotation of the motor and handpiece A red LED light displays the reverse rotation 6 Ratio Selector Calibrates the RPM display to read accurately for up to four different han...

Page 7: ...h the pump to the ON position The display will light Set the flow to the desired level Thorough cleaning and lubrication of hand pieces after each use and before steriliza tion is very important to ensure proper operation and service life of the handpiece Follow the instructions provided with the handpiece purchased for complete mainte nance instructions NOTE The RPM display indicates true bur spe...

Page 8: ...otor and cord Loosely coil the motor cord when auto claving Avoid sharply bending the cord when autoclaving NOTE Call Aseptico Inc at 1 800 426 5913 for any questions or clarifications on this sterilization procedure Always install the autoclaving plugs into motor and motor connector before autoclaving If the autoclaving plug for the motor becomes difficult to remove or install apply silicone grea...

Page 9: ... If blown replace with 1A 250V slo blo fuse for 110 volts 0 5A 250V slo blo fuse for 220 volts Check motor plug connection Check foot switch connection Depress foot switch Increase RPM Check that bur is properly seated in the handpiece and the collet is closed Check that pump is on and flow level is sufficient Check that water container seal is completely punctured Make sure the irrigation tubing ...

Page 10: ...8 NOTES ...

Page 11: ...NOTES ...

Page 12: ...tion In the event of alleged defect under warranty the purchaser is to notify Aseptico s Customer Service Department promptly Customer Service will provide instructions usually directing that the product be returned for service Shipment to Aseptico and the cost thereof is always the responsibility of the purchaser Accidental misuse inappropriate installation or failure to perform directed maintena...