AMC‑15
SAFETY PRECAUTIONS
To prevent injury to people and damage to property, please heed relevant warnings and remarks. They are marked as follows:
• WARNING
: Serious injury or death may result if ignored.
• CAUTION
: Damage to property or the environment may result if ignored.
• NOTE
: Important additional information and hints.
Aseptico accepts no liability for direct or consequential injury or dam-
age resulting from improper use, arising in particular through the
non-observance of the operating instructions, or improper preparation
and maintenance.
s
WARNING:
To avoid the risk of electric shock, this equipment
must only be connected to a supply mains with protective earth.
s
WARNING:
Connecting electrical equipment to this device cre-
ates a Medical Electrical (ME) system. If connecting equipment
that is not part of the ME system, have a trained service person
evaluate the ME system to ensure safety leakage currents are
maintained per IEC 60601-1.
s
WARNING:
Clean, disinfect, and sterilize new or repaired hand-
pieces and instruments before first use and between each
patient use. Only use sterilized handpieces and instruments
during treatment. Non-sterilized handpieces and instruments
may cause bacterial or viral infections. Always sterilize hand-
pieces and instruments after operation.
s
CAUTION:
Always examine unit components for damage
before commencing treatment. Damaged components must
not be used and must be replaced.
s
CAUTION:
For device transport, always keep the pull handle in
hand during transport and ensure stable platform before releas-
ing.
s
WARNING:
Use for intended purposes only. Failure to observe
the operating instructions may result in the patient or user suf-
fering serious injury or the product being damaged, possibly
beyond repair. Before using this product, make sure that you
have studied and understood the operating instructions.
s
WARNING:
For use by qualified and trained personnel only.
s
WARNING:
Do not install where there is a risk of an explosion.
The Mobile Dental Cart is not intended for operation in the pres-
ence of flammable anesthetics or gases.
s
WARNING:
Always operate a high-speed handpiece with water
coolant. Operating a high-speed handpiece without water cool-
ant can cause thermal injury to the patient.
s
CAUTION:
Observe local regulations concerning disposal of
amalgam waste.
s
WARNING:
Never operate unit or work on patients when the
top lid is open.
s
WARNING:
Do not use this device for dental implant proce-
dures.
s
CAUTION:
Do not run saline solutions through the water sys-
tem—saline will corrode the plumbing.
s
WARNING:
Do not position the unit so that the power cord is
inaccessible to unplug during normal use.
s
WARNING:
No modification of this equipment is allowed.
s
CAUTION:
Dispose of all medical waste products, residues,
equipment and etc. in accordance with local Regulations.
s
CAUTION:
All repairs are to be performed by Authorized Repair
Personnel only. Aseptico offers servicing of equipment that is
out of warranty and this is highly recommended to ensure opti-
mal performance and product life. Circuit diagrams, parts list
and requested relevant servicing information will be provided
upon request.
s
CAUTION:
Do not use CaviCide™ cleaner on the unit.
s
CAUTION:
Do not plug 230V power supply into the 115V version
of the unit.
s
NOTE:
The emissions characteristics of this equipment make it
suitable for use in industrial areas and hospitals (CISPR 11 class
A). If it is used in a residential environment (for which CISPR 11
class B is normally required) this equipment might not offer ade-
quate protection to radio-frequency communication services.
The user might need to take mitigation measures, such as relo-
cating or re-orienting the equipment.
s
WARNING:
Use of this equipment adjacent to or stacked with
other equipment should be avoided because it could result in
improper operation. If such use is necessary, this equipment
and the other equipment should be observed to verify that they
are operating normally.
s
WARNING:
Use of accessories, transducers and cables other
than those specified or provided by the manufacturer of this
equipment could result in increased electromagnetic emissions
or decreased electromagnetic immunity of this equipment and
result in improper operation.
s
WARNING:
Portable RF communications equipment (includ-
ing peripherals such as antenna cables and external antennas)
should be used no closer than 30 cm (12 inches) to any part of
the unit, including cables specified by the manufacturer. Other-
wise, degradation of the performance of this equipment could
result.