AMC‑15

 SAFETY PRECAUTIONS

To prevent injury to people and damage to property, please heed relevant warnings and remarks. They are marked as follows:

• WARNING

: Serious injury or death may result if ignored.

• CAUTION

: Damage to property or the environment may result if ignored.

• NOTE

: Important additional information and hints.

Aseptico accepts no liability for direct or consequential injury or dam-

age resulting from improper use, arising in particular through the 

non-observance of the operating instructions, or improper preparation 

and maintenance.

WARNING: 

To avoid the risk of electric shock, this equipment 

must only be connected to a supply mains with protective earth.

WARNING: 

Connecting electrical equipment to this device cre-

ates a Medical Electrical (ME) system. If connecting equipment 

that is not part of the ME system, have a trained service person 

evaluate the ME system to ensure safety leakage currents are 

maintained per IEC 60601-1.

WARNING: 

Clean, disinfect, and sterilize new or repaired hand-

pieces and instruments before first use and between each 

patient use. Only use sterilized handpieces and instruments 

during treatment. Non-sterilized handpieces and instruments 

may cause bacterial or viral infections. Always sterilize hand-

pieces and instruments after operation.

CAUTION: 

Always examine unit components for damage 

before commencing treatment. Damaged components must 

not be used and must be replaced.

CAUTION: 

For device transport, always keep the pull handle in 

hand during transport and ensure stable platform before releas-

ing.

WARNING:

 Use for intended purposes only. Failure to observe 

the operating instructions may result in the patient or user suf-

fering serious injury or the product being damaged, possibly 

beyond repair. Before using this product, make sure that you 

have studied and understood the operating instructions.

WARNING:

 For use by qualified and trained personnel only.

WARNING:

 Do not install where there is a risk of an explosion. 

The Mobile Dental Cart is not intended for operation in the pres-

ence of flammable anesthetics or gases. 

WARNING: 

Always operate a high-speed handpiece with water 

coolant. Operating a high-speed handpiece without water cool-

ant can cause thermal injury to the patient.

CAUTION:

 Observe local regulations concerning disposal of 

amalgam waste.

WARNING:

 Never operate unit or work on patients when the 

top lid is open.

WARNING:

 Do not use this device for dental implant proce-

dures.

CAUTION:

 Do not run saline solutions through the water sys-

tem—saline will corrode the plumbing.

WARNING:

 Do not position the unit so that the power cord is 

inaccessible to unplug during normal use.

WARNING:

 No modification of this equipment is allowed.

CAUTION:

 Dispose of all medical waste products, residues, 

equipment and etc. in accordance with local Regulations.

CAUTION:

 All repairs are to be performed by Authorized Repair 

Personnel only. Aseptico offers servicing of equipment that is 

out of warranty and this is highly recommended to ensure opti-

mal performance and product life. Circuit diagrams, parts list 

and requested relevant servicing information will be provided 

upon request.

CAUTION:

 Do not use CaviCide™ cleaner on the unit.

CAUTION:

 Do not plug 230V power supply into the 115V version 

of the unit.

NOTE:

 The emissions characteristics of this equipment make it 

suitable for use in industrial areas and hospitals (CISPR 11 class 

A). If it is used in a residential environment (for which CISPR 11 

class B is normally required) this equipment might not offer ade-

quate protection to radio-frequency communication services. 

The user might need to take mitigation measures, such as relo-

cating or re-orienting the equipment.  

WARNING:

 Use of this equipment adjacent to or stacked with 

other equipment should be avoided because it could result in 

improper operation. If such use is necessary, this equipment 

and the other equipment should be observed to verify that they 

are operating normally.

WARNING:

 Use of accessories, transducers and cables other 

than those specified or provided by the manufacturer of this 

equipment could result in increased electromagnetic emissions 

or decreased electromagnetic immunity of this equipment and 

result in improper operation.

WARNING:

 Portable RF communications equipment (includ-

ing peripherals such as antenna cables and external antennas) 

should be used no closer than 30 cm (12 inches) to any part of 

the unit, including cables specified by the manufacturer. Other-

wise, degradation of the performance of this equipment could 

result.

Summary of Contents for AMC-15

Page 1: ...OPERATION MAINTENANCE MANUAL AMC 15 Mobile Dental Cart...

Page 2: ...d handpiece without water cool ant can cause thermal injury to the patient s CAUTION Observe local regulations concerning disposal of amalgam waste s WARNING Never operate unit or work on patients whe...

Page 3: ...The AMC 15 is available in either a 115V or 230V power supply configuration OPTIONAL EQUIPMENT Purchased Separately PN 730595 Filter Replacement Amalgam Separator PN AA 20A Auxiliary Arm with Accesso...

Page 4: ...4 AMC 15 FRONT VIEW Instrument Holders Hinged Top Lid Auxiliary Water Connection Bulkhead Connectors Handpiece Pressure Gauge Waste Indicator Tank Full or Cable Disconnected...

Page 5: ...lant Bottle Selector Bottle Pressure Release Flush Toggle Air Coolant Foot Control w Water Valve Water Supply Bottles Rear Caster w Brake Accessory Arm w Tray optional Optional Equipment shaded Clear...

Page 6: ...ssure Gauge Central Vacuum Cannister Amalgam Solids Trap inside System Pressure Regulator factory set Air Flow Adjustment Block Syringe Flow Adjustment Block Instrument Holder Arm Amalgam Separator By...

Page 7: ...ket Waste Sensor Connector Waste Tank Waste Pump Waste Hose w Clamp Waste Compartment Latch Waste Pump Switch Waste Pump Circuit Breaker Air Tank Purge Valve Air Tank Drain Optional Equipment shaded B...

Page 8: ...tor A into the amalgam man ifold B You will need to loosen the retaining screw C located under the top lid to get the bracket down and around the lip of the amalgam separator Tighten the retaining scr...

Page 9: ...tch B towards the dot C on the foot control as shown Toggle the switch away from the dot to disable water coolant 2 INSTRUMENT HOLDERS Each instrument holder except the syringe holder provides an on o...

Page 10: ...teps for the HP 2 handpiece using the HP 2 valve B A 7 AIR COOLANT Air coolant chip air works in combina tion with the water coolant setting to create a fine mist for the working handpiece Make sure t...

Page 11: ...oses with a disinfectant solution 3 AMALGAM SEPARATOR The optional amalgam separator A is located in the waste compartment The separator filters out particu late matter while the waste water is being...

Page 12: ...TION Do not run saline solutions through the water system saline will corrode the plumbing 8 3 WAY AIR WATER SYRINGE The syringe tip is autoclav able To remove a tip from the syringe press down on the...

Page 13: ...ter coolant valve to the selected handpiece is open No coolant air to handpiece Check that the air coolant toggle is in the ON position Check that the air coolant flow control valve is open Waste pump...

Page 14: ...ith all optional equipment 139 lb 63 kg Shipping Crate Size 30 0 W x 37 0 L x 50 0 H 76 2 cm x 93 9 cm x 127 cm Shipping Crate Weight 72 lb 32 7 kg Power Source 115V version 115V 60Hz 230V version 230...

Page 15: ...tion 2012 Disposing of your old product Each Member State in the European Union EU requires that the waste from electrical and electronic products be disposed of sepa rately from normal household wast...

Page 16: ...chor eye bolts B on the base 5 Place the boxed foot control pedal A under the cart 6 Wrap the cart with pallet stretch wrap 7 Insert the cardboard end panels and side panels into the crate base making...

Page 17: ...17 AMC 15 NOTES...

Page 18: ...18 AMC 15...

Page 19: ...19 AMC 15...

Page 20: ...P O Box 1548 Woodinville WA 98072 1548 800 426 5913 425 487 3157 Fax 425 487 2608 www aseptico com info aseptico com P N 421208 Rev A ECO 14949 06 2020 PRINTED IN THE USA...

Reviews: