5

AMC‑15

SIDE V

IE

W

Control Panel:

•Water Coolant

•Bottle Selector

• Bottle Pressure Release

•Flush Toggle

•Air Coolant

Foot Control w/ Water Valve

Water Supply Bottles

Rear Caster w/ Brake

Accessory Arm w/ Tray

(optional)

Optional Equipment (shaded)

Clear Water Bottles

w/ Level Indicators

(optional)

Summary of Contents for AMC-15

Page 1: ...OPERATION MAINTENANCE MANUAL AMC 15 Mobile Dental Cart...

Page 2: ...d handpiece without water cool ant can cause thermal injury to the patient s CAUTION Observe local regulations concerning disposal of amalgam waste s WARNING Never operate unit or work on patients whe...

Page 3: ...The AMC 15 is available in either a 115V or 230V power supply configuration OPTIONAL EQUIPMENT Purchased Separately PN 730595 Filter Replacement Amalgam Separator PN AA 20A Auxiliary Arm with Accesso...

Page 4: ...4 AMC 15 FRONT VIEW Instrument Holders Hinged Top Lid Auxiliary Water Connection Bulkhead Connectors Handpiece Pressure Gauge Waste Indicator Tank Full or Cable Disconnected...

Page 5: ...lant Bottle Selector Bottle Pressure Release Flush Toggle Air Coolant Foot Control w Water Valve Water Supply Bottles Rear Caster w Brake Accessory Arm w Tray optional Optional Equipment shaded Clear...

Page 6: ...ssure Gauge Central Vacuum Cannister Amalgam Solids Trap inside System Pressure Regulator factory set Air Flow Adjustment Block Syringe Flow Adjustment Block Instrument Holder Arm Amalgam Separator By...

Page 7: ...ket Waste Sensor Connector Waste Tank Waste Pump Waste Hose w Clamp Waste Compartment Latch Waste Pump Switch Waste Pump Circuit Breaker Air Tank Purge Valve Air Tank Drain Optional Equipment shaded B...

Page 8: ...tor A into the amalgam man ifold B You will need to loosen the retaining screw C located under the top lid to get the bracket down and around the lip of the amalgam separator Tighten the retaining scr...

Page 9: ...tch B towards the dot C on the foot control as shown Toggle the switch away from the dot to disable water coolant 2 INSTRUMENT HOLDERS Each instrument holder except the syringe holder provides an on o...

Page 10: ...teps for the HP 2 handpiece using the HP 2 valve B A 7 AIR COOLANT Air coolant chip air works in combina tion with the water coolant setting to create a fine mist for the working handpiece Make sure t...

Page 11: ...oses with a disinfectant solution 3 AMALGAM SEPARATOR The optional amalgam separator A is located in the waste compartment The separator filters out particu late matter while the waste water is being...

Page 12: ...TION Do not run saline solutions through the water system saline will corrode the plumbing 8 3 WAY AIR WATER SYRINGE The syringe tip is autoclav able To remove a tip from the syringe press down on the...

Page 13: ...ter coolant valve to the selected handpiece is open No coolant air to handpiece Check that the air coolant toggle is in the ON position Check that the air coolant flow control valve is open Waste pump...

Page 14: ...ith all optional equipment 139 lb 63 kg Shipping Crate Size 30 0 W x 37 0 L x 50 0 H 76 2 cm x 93 9 cm x 127 cm Shipping Crate Weight 72 lb 32 7 kg Power Source 115V version 115V 60Hz 230V version 230...

Page 15: ...tion 2012 Disposing of your old product Each Member State in the European Union EU requires that the waste from electrical and electronic products be disposed of sepa rately from normal household wast...

Page 16: ...chor eye bolts B on the base 5 Place the boxed foot control pedal A under the cart 6 Wrap the cart with pallet stretch wrap 7 Insert the cardboard end panels and side panels into the crate base making...

Page 17: ...17 AMC 15 NOTES...