2.
SAFETY PRECAUTIONS:
Aseptico accepts no liability for direct or consequential injury or damage resulting from improper
use, arising in particular through the non-observance of the operating instructions, or improper
preparation and maintenance.
WARNING:
Clean, disinfect, and sterilize new or repaired handpieces and instruments before
first use and between each patient use. Only use sterilized handpieces and
instruments during treatment. Non-sterilized handpieces and instruments may cause
bacterial or viral infections. Always sterilize handpieces and instruments after
operation.
CAUTION:
Always examine unit components for damage before commencing treatment.
Damaged components must not be used and must be replaced.
WARNING:
Use for intended purposes only. Failure to observe the operating instructions may
result in the patient or user suffering serious injury or the product being damaged,
possibly beyond repair. Before using this product, make sure that you have studied
and understood the operating instructions.
WARNING:
For use by qualified and trained personnel only.
WARNING:
Do not install where there is a risk of an explosion. The Mobile Dental System is not
intended for operation in the presence of flammable anesthetics or gases.
WARNING:
Always operate a high-speed handpiece with water coolant. Operating a high-speed
handpiece without water coolant can cause thermal injury to the patient.
CAUTION:
Observe local regulations concerning disposal of amalgam waste.
WARNING:
Never operate unit or work on patients when the top cover is open.
WARNING:
Do not use this device for dental implant procedures.
CAUTION:
Do not run saline solutions through the water system -- saline will corrode the water
filters.
WARNING:
CONTRAINDICATIONS
Ultrasonic oscillations emitted by the optional Ultrasonic Scaler may prevent the
proper function of cardiac pacemakers. Therefore, Aseptico recommends that
patients with a cardiac pacemaker should not be treated with the Ultrasonic Scaler
component of the AMC-20 Cart.
WARNING:
The optional Ultrasonic Scaler instrument tips oscillate at high frequency and can
fracture during operation. To help prevent the tips from fracturing and possibly
injuring the patient, always follow the scaler manufacturer's operating instructions
and recommended ultrasonic power settings.
WARNING:
Do not use the optional Ultrasonic Scaler dry. If used dry, the Instrument Tip will heat
immediately. This may cause thermal injury to the tooth. Ensure that adequate liquid
coolant is always available.
WARNING:
Avoid looking directly into the optional Curing Light. Protect patient's eyes with
darkened eyewear when using the Curing Light Probe.
CAUTION:
The lens for the optional electric motor LED is soft and can be damaged. If lens
needs to be cleaned, use a lint-free swab and isopropyl alcohol - do not use other
solvents as they might adversely react with the LED assembly.
CAUTION:
The AEU-5000 Electric Motor is not recommended for use with endodontic files that
have torque limit requirements less than 100 g-cm.
OPTIONAL EQUIPMENT SAFETY PRECAUTIONS: