IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
TThis heater must have a non-combustible floor
protector (UL1618 ember protection) installed
beneath it if the floor is of combustible material.
The floor protector should be listed to UL 1618 or
equivalent to type 1 ember floor protection. The
floor protection must extend 6” to the front, 6” on
each side and 1” to the rear of the appliance See
diagram for further information.
A Back to Stove
1”
26mm
B Side to Stove
6” 153 mm
C Front to Stove
6” 153 mm
D Back to Flue
2”
51 mm
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home in
accordance with the clearances given below. For
safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in
clearance to combustibles may only be done by
means approved by a regulatory authority.
E
Side Wall to Stove
8”
235 mm
F
Side Wall to PL Vent
Pipe
10”
254 mm
G Back Wall to Stove
9.25”
235 mm
H Back Wall to PL Vent
Pipe
3”
76 mm
J
Ceiling to Floor
60”
1524 mm
K
Ceiling to Stove
27.5
699 mm
L
Wall to Stove
7-1/2”
191 mm
M Side Wall to PL Vent
Pipe
11-1/4”
286 mm
N
Wall to PL Vent Pipe
7-1/2”
191 mm
INSTALLATION