Listed Termination
Flashing
36” (900 mm)
3” (75 mm) Clearance
to Combustibles
Use Ceiling Firestop
3” (75mm) Clearance
to Combustibles
3” (75 mm)
Tee with
Cleanout
6” (150 mm)
Combustion Air
Intake with approved cap
Non-Combustible
Floor Protection
Existing Combustible
Floor
6” (150 mm)
Use Ceiling Firestop
3” (75mm) Clearance
to Combustibles
FREESTANDING INTERIOR VERTICAL INSTALLATION
1. Locate your Pellet Stove Room Heater in a location
which meets the requirements of this manual, but in an
area where it does not interfere with the house framing,
wiring, etc.
2. Install a non-combustible hearth pad underneath the pel-
let stove. This pad should extend at least 6” (152mm) in
front of the unit.
3. Place your Pellet Stove Room Heater on the hearth
pad and locate the unit in a manner that will leave the
exhaust vent with a minimum of 3” (75mm) clearance to
any combustible wall.
4. When installing the air intake, locate the center of the
combustion air intake pipe at the back of your unit. Line
up the center with the same spot on your exterior wall
and cut a 2-1/2” (64mm) diameter hole through the wall.
5. Install the combustion air intake pipe.
6. Secure all vent joint connections with 3 screws. Seal the
exhaust vent joint connections with high temperature
silicone sealant.
7. Install a tee, with a cleanout, on the exhaust pipe found
at the rear of your unit.
8. Install approved vent upward through the ceiling. When
you pass through the combustible framing ensure that the
appropriate ceiling
fi
re stop is used. You must maintain a
minimum 3” (75mm) clearance to combustibles and keep
any insulation away from the exhaust vent.
9. Extend the exhaust vent through the roof
fl
ashing and
ensure that the vertical cap is approximately 36” (900mm)
above the roof.
Installation
13