8
SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - Do not install in a sleeping room
CAUTION! - The structural integrity of the mobile home floor, wall, and ceiling/roof must be
maintained
.
In addition to the previously detailed installation requirements, mobile home installations must meet the
following requirements:
• The heater must be permanently attached to the floor.
1.
There are two holes in the pedestal base, use 3/8” bolts through the floor.
2.
To attach the leg model use two 3/8-16 UNC bolts through the floor.
•
The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire
using a serrated or star washer to penetrate paint or protective coating to ensure grounding.
•
When moving your mobile home, all exterior venting must be removed while the mobile home is being
relocated. After relocation, all venting must be reinstalled and securely fastened.
•
Outside Air is mandatory for mobile home installation. See your dealer for purchasing.
• Check with your local building officials as other codes may apply.
Mobile Home Attachment