background image

CHIMNEY MAINTENANCE

SMOKE & CO MONITORS

Burning wood naturally produces smoke and 

carbon monoxide(CO) emissions. CO is a poisonous 

gas when exposed to elevated concentrations for 

extended periods. While the modern combustion 

systems in heaters drastically reduce the amount of 

CO emitted out the chimney, exposure to the gases 

in closed or confined areas can be dangerous. Make 

sure your stove gaskets and chimney joints are in 

good working order and sealing properly to ensure 

unintended exposure. It is recommended that you 

use both smoke and CO monitors in areas having 

the potential to generate CO.

GLASS CARE

•  Inspect and clean the glass regularly to detect 

any cracks. If you spot one, turn the stove off 

immediately. Do not abuse the glass door by 

striking or slamming shut. Do not use the stove if 

the glass is broken.

•  If the glass on your stove breaks, replace only with 

the glass supplied from your heater dealer. Never 

substitute other materials for the glass.

•  To replace the glass, remove the screws retaining 

the glass moldings inside the door. Remove the 

moldings and replace the damaged piece with a 

new one. Perform the procedure backward after 

replacing it. When replacing the glass, you should 

change the glass gasket to make sure you keep it 

sealed.

•  Never wash the glass with a product that may 

scratch.  Use  a  specialized  product,  available  in 

the stores where wood stoves are sold. The glass 

should be washed only when cold.

GASKET CARE

WARNING:

NEVER OPERATE THE STOVE WITHOUT A 

GASKET OR WITH A BROKEN ONE. DAMAGE 

TO THE STOVE OR EVEN HOUSE FIRE MAY 

RESULT.

This  unit’s  door  uses  a  3/4”  diameter  rope  gasket. 

It is recommended that you change the door 

gasket  (which  makes  your  stove  door  air  tight) 

once a year, in order to ensure good control over 

the combustion, maximum efficiency and security. 

To change the door gasket, simply remove the 

damaged one. Carefully clean the available gasket 

groove, apply a high temperature silicone sold for 

this purpose, and install the new gasket. You may 

light up your stove again approximately 24 hours 

after having completed this operation.

For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: parts@usstove.com

The  information  in  this  owner’s  manual  is  specific  to  your  unit.  When  ordering  replacement  parts  the 

information in this manual will help to ensure the correct items are ordered. Before contacting customer 

service write down the model number and the serial number of this unit. That information can be found on 

the certification label attached to the back of the unit. Other information that may be needed would be the 

part number and part description of the item(s) in question. Part numbers and descriptions can be found 

in the “Repair Parts” section of this manual. Once this information has been gathered you can contact 

customer service by phone 1-800-750-2723 Ext 5051 or Email  parts@usstove.com.

Model Information

Model Number
Serial Number

HOW TO ORDER REPAIR PARTS

16

© 2021 United States Stove Company

Summary of Contents for AW2520E-BL

Page 1: ...lation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Reference CALIFORNIA PROPOSITION 65 WARNING This pr...

Page 2: ...0E pedestal 25 6 650 mm 27 686 mm 31 4 798 mm Combustion Chamber Width x Depth 22 3 4 x 16 5 8 578 mm x 423 mm Volume Cubic Feet 2 73 cubic feet Door Opening Width x Height 18 x 9 3 4 458 mm x 248 mm Pyroceramic Glass Door Viewing Width x Height 16 x 10 3 407 mm x 261 mm Optional Accessories Outside Air Intake Kit 4FAK INTRODUCTION CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITU...

Page 3: ...f no date of inspection of the existing chimney system __________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual Check the operations of the air controls Co...

Page 4: ...the source of electrical supply before attempting the installation The blower assembly is intended for use only with a stove that is marked to indicate such use Do not route the supply cord near or across hot surfaces Fix the assembly to the back of the stove with the four screws provided ASH PAN ASSEMBLY Remove ash pan from firebox Under the firebox there are two brackets Slide the ash pan into t...

Page 5: ...ED WHEN REQUIRED US Stove highly recommends your stove be installed by a qualified NFI US or WETT Canada technician To find the nearest qualified installer go to https nficertified org https www wettinc ca POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that willfavorthemostefficientheatdistributionpossible throughout the hou...

Page 6: ...l run that extends 2 beyond each side of the flue pipe The chimney connector must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling ForCanadianinstallations wherepassagethrough a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossing a combustible wall must have a minimum clearance of ...

Page 7: ... MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOOR 1 The bracket engages around the square extrusion of the leveling bolt inserted into the leg 2 Once appliance is leveled position the bracket and attach to the floor using the appropriate hardware ...

Page 8: ...ates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built or masonry chimney If you are using a factory built chimney it must comply with UL 103 or CSA B365 standard therefore it must be a Type HT 2100 F It must be installed according to the manufacturer s specifications Take into account the chimney s location to ensure it is not too close to neighbors or in a valley...

Page 9: ...eets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Be sure to the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Sheathing Airtight C...

Page 10: ...t metal support Maintain the 6 153 mm space There should also be a support sized to fit and hold the metal chimney connector See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner METHOD D 2 51 mm Clearance to Combustible Wall Member Start with a solid pak listed factory built chim...

Page 11: ... INSULATION REMOVED WOOD STOVE UTILIZATION Your heating appliance was designed to burn well seasoned natural wood only no other materials should be burned Any type of well seasoned natural wood may be used in your stove but specific varieties have better energy yields than others Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softw...

Page 12: ...w the stove reacts You can increase the number of logs burned at a time but make sure the temperature never rises higher than 475 F 246 C on a magnetic thermometer for installation on single wall stove pipes or 900 F 482 C on a probe thermometer for installation on double wall stove pipe The thermometer should be placed about 18 457 mm above the stove Higher temperatures can lead to overheat and d...

Page 13: ... unseasoned wet wood only hurts your stoves efficiency and leads to accelerated creosote buildup in your chimney Be considerate of the environment and only burn dry wood CAUTION DO NOT LEAVE APPLIANCE UNATTENDED THE WITH DOOR OPEN For a cold start up place 4 to 5 pieces of newspaper into the firebox On top of the newspaper lay 4 lbs of kindling in random placement to ensure airflow through the kin...

Page 14: ...t the air settings of your specific unit to produce the smallest amount of visible smoke Wood that has not been seasoned properly and has a high wood moisture content will produce excess visible smoke and burn poorly AIR TUBES The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration of these tubes may...

Page 15: ...rn dry wood This allows clean burns and higher chimney temperatures therefore less creosote deposit Leave the air control fully open for about 5 min every time you reload the stove to bring it back to proper operating temperatures The secondary combustion can only take place if the firebox is hot enough Always check for creosote deposit once every two months and have your chimney cleaned at least ...

Page 16: ...are sold The glass should be washed only when cold GASKET CARE WARNING NEVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE DAMAGE TO THE STOVE OR EVEN HOUSE FIRE MAY RESULT This unit s door uses a 3 4 diameter rope gasket It is recommended that you change the door gasket which makes your stove door air tight once a year in order to ensure good control over the combustion maximum efficien...

Page 17: ...20E BL 4 12 891496 Hearth Trim 24 1 13 25826 Hearth Plate 1 14 891495 Hearth Trim 18 1 15 29071 Ash Pan 1 16 891137 Brushed Nickel Handle 1 17 610066 Slide Retainer Weldment 1 18 610068 Damper Slide Weldment 1 19 86954 Damper Rod 1 20 891331 Spring Handle Brushed Nickel 1 REPAIR PARTS IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOU...

Page 18: ...nel 1 7 24103A Half Firebrick Pumice 4 1 2 X 4 1 2 1 8 40561 Ash Plug 1 9 891530A Firebrick 4 5 X 7 5 X 1 25 1 10 89066A Firebrick Pumice 4 1 2 X 9 18 11 891414A Half Firebrick 2 9 11 10 8 7 6 5 1 2 3 4 7 8 6 5 2 3 4 1 Key Part Description Qty 1 893240 AW Complete Door Handle 1 2 891373 Door Hinge Pad 2 3 40882 Lg Arched Door 1 4 88082 Rope Gasket 3 4 1 5 892204 Glass 1 6 26314 Gasket Clamp 1 7 29...

Page 19: ...________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No _________________________...

Page 20: ...NOTES 20 2021 United States Stove Company ...

Page 21: ...NOTES 2021 United States Stove Company 21 ...

Page 22: ...ticles Remplacé _____________________________ Service de 07 Date _____________________ Nom de l ingénieur ____________________________ N de licence __________________________________ Compagnie ___________________________________ N de téléphone _______________________________ Poêle Inspecté Cheminée balayée Articles Remplacé _____________________________ Service de 02 Date _____________________ Nom...

Page 23: ...nce de verre inférieure 2 8 29166 Pince de verre latérale 2 PIÈCES DE RECHANGE Pour commander des pièces Appelez le 1 800 750 2723 Ext 5051 ou Envoyez un courriel à parts usstove com Clé Partie Description Qté 1 88325 Couverture en laine Kao 1 2 88138 Panneau de fibres de céramique 1 3 86643 Tube à air secondaire Ø5 32 2 4 29247 Panneau de brique droit 1 5 86645 Tube à air secondaire Ø7 32 2 6 292...

Page 24: ... 1 5 26060 Bouclier arrière 1 6 610926 Cendrier arrière AW2520E BP 1 7 29243 Piédestal AW2520E BP 1 8 29065 Front de piédestal AW2520E BP 1 9 610969 Soudure de la base du piédestal AW2520E BP 1 10 610968 Ashpan Housing AW2520E BL 1 11 40566 Pied en fonte AW2520E BL 4 12 891496 Garniture de foyer 24 po 13 25826 Plaque de foyer 1 14 891495 Garniture de foyer 18 po 1 15 29071 Cendrier 1 16 891137 Poi...

Page 25: ... où les poêles à bois sont vendus Le verre ne doit être lavé qu à froid ENTRETIEN DES JOINT AVERTISSEMENT N UTILISEZ JAMAIS LE POÊLE SANS JOINT OU AVEC UN CASSÉ DES DOMMAGES AU POÊLE OU À L INCENDIE DE LA MAISON PEUVENT EN RÉSULTER La porte de cet appareil utilise un joint de corde de 3 4 po de diamètre Il est recommandé de changer le joint de porte qui rend la porte de votre poêle étanche à l air...

Page 26: ...rdue dans l atmosphère POUR ÉVITER LA CONSTRUCTION DE CRÉOSOTE Brûlez toujours du bois sec Cela permet des brûlures propres et des températures de cheminée plus élevées donc moins de dépôt de créosote Laissez le contrôle d air complètement ouvert pendant environ 5 min chaque fois que vous rechargez le poêle pour le ramener à des températures de fonctionnement appropriées La combustion secondaire n...

Page 27: ... régler les paramètres d air de votre unité spécifique pour produire la plus petite quantité de fumée visible Le bois qui n a pas été correctement séché et qui a une teneur élevée en humidité produira un excès de fumée visible et brûlera mal CONDUITS D AIR Les conduits d air assemblés dans cette unité sont conçus pour offrir un mélange précis d air secondaire et assurer une plus grande efficacité ...

Page 28: ...élérée de créosote dans votre cheminée Soyez respectueux de l environnement et ne brûlez que du bois sec ATTENTION NE LAISSEZ PAS L APPAREIL SANS SURVEILLANCE AVEC LA PORTE OUVERTE Pour un démarrage à froid placez 4 à 5 morceaux de papier journal dans la chambre de combustion Sur le dessus du journal déposez 4 lb de bois d allumage dans un placement aléatoire pour assurer la circulation de l air à...

Page 29: ...urez vous que la température ne dépasse jamais 475 F 246 C sur un thermomètre magnétique pour une installation sur des tuyaux de poêle à paroi simple ou 900 F 482 C sur un thermomètre à sonde pour installation sur tuyau de poêle à double paroi Le thermomètre doit être placé à environ 18 po 457 mm au dessus du poêle Des températures plus élevées peuvent entraîner une surchauffe et endommager votre ...

Page 30: ...ÉGAGEMENTS DES SURFACES COMBUSTIBLES SPÉCIFIÉES POUR CET APPAREIL NE JAMAIS FAIRE FONCTIONNER AVEC DES TUBES SECONDAIRES UN CARTON DE FIBRE OU UNE ISOLATION RETIRÉE UTILISATION DU POÊLE À BOIS Votre appareil de chauffage a été conçu pour brûler uniquement du bois naturel bien séché aucun autre matériau ne doit être brûlé N importe quel type de bois naturel bien séché peut être utilisé dans votre p...

Page 31: ...rie Supports de tôle d acier Conduit de cheminée Conduit de raccordement Le dégagement minimum de la cheminée aux supports en tôle d acier et aux matériaux combustibles est de 5 cm 2 po 50 8 mm Deux canaux d aération de 2 5 cm 1 po chacun 25 4 mm Deux canaux d aération de 2 5 cm 1 po chacun 25 4 mm Fabriqués en tôle d acier Isolant de fibre de verre d un minimum de 152 4 mm 6 po Méthode D Dégagement ...

Page 32: ... utilisant des briques d une épaisseur minimale de 3 5 po 89 mm et un revêtement en argile d une épaisseur minimale de 5 8 po 15 9 mm construisez un passage à travers la paroi Le revêtement en argile doit être conforme à l ASTM C315 Spécification standard des revêtements réfractaires en argile ou son équivalent Maintenez un minimum de 12 po 304 8 mm de maçonnerie en briques entre le revêtement en ...

Page 33: ...talliques ou d argile scellées avec du ciment réfractaire Les conduits ronds sont les plus efficaces Le diamètre intérieur du conduit de cheminée doit être identique à celui de l évacuation des fumées du poêle Un conduit trop petit peut poser des problèmes de tirage tandis qu un gros conduit favorise un refroidissement rapide du gaz et donc l accumulation de créosote et le risque d incendies de ch...

Page 34: ...S PIEDS AU SOL 1 Le support s engage autour de l extrusion carrée du boulon de nivellement inséré dans le pied 2 Une fois l appareil nivelé positionnez le support et fixez le au sol à l aide du matériel approprié nécessaire pour votre revêtement de sol spécifique 3 Installez un support par pied ou consultez les autorités locales compétentes pour déterminer le nombre de points de fixation requis En...

Page 35: ...po au delà de chaque côté du conduit de fumée Le raccord de cheminée ne doit pas traverser un grenier ou un espace sur le toit un placard ou un espace dissimulé similaire un plancher ou un plafond Pour les installations canadiennes où le passage à travers un mur ou une cloison de construction combustible est souhaité l installation doit être conforme à la norme CAN CSA B365 Un conduit de fumée tra...

Page 36: ...ONDUIT OU CIRCUIT DE DISTRIBUTION D AIR UNE SOURCE D AIR FRAIS DANS LA PIÈCE OU L ESPACE CHAUFFÉ DEVRA ÊTRE FOURNIE SI NÉCESSAIRE US Stove recommande fortement que votre poêle soit installé par un technicien qualifié NFI US ou WETT Canada Pour trouver l installateur qualifié le plus proche accédez à https nficertified org or https www wettinc ca POSITIONNEMENT DU POÊLE Il est très important de pos...

Page 37: ...électrique avant de tenter l installation L ensemble souffleur est destiné à être utilisé uniquement avec un poêle qui est marqué pour indiquer une telle utilisation Ne faites pas passer le cordon d alimentation à proximité ou sur des surfaces chaudes Fixez l ensemble à l arrière du poêle avec les quatre vis fournies ASSEMBLAGE DU BAC À CENDRES Enlevez la casserole de cendre du foyer Sous le foyer...

Page 38: ...pection du système de cheminée existant _________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et de l étanchéité de la porte Confirmer les dégagements aux combustibles selon les instructions d installation ...

Page 39: ...x Hauteur AW2520E jambe 25 5 po 648 mm 29 4 po 747 mm 31 3 po 796 mm AW2520E piédestal 25 6 po 650 mm 27 po 686 mm 31 4 po 798 mm Chambre de combustion Largeur x Profondeur 22 3 4po x 16 5 8po 578 mm x 423 mm Volume Pieds cubes 2 73 pieds cubes Ouverture de la porte Largeur x Hauteur 18 po x 9 3 4 po 458 mm x 248 mm Porte en verre pyrocéramique Visualisation Largeur x Hauteur 16 po x 10 3 po 407 m...

Page 40: ... votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages matériels des blessures corporelles ou même la mort Une installation incorrecte pourrait annuler votre garantie Conservez ces instructions dans un endroit sûr pour réf...

Reviews: