CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation
of the stove. Refer to the tables below:
•
Floor to ceiling height must be at least 7’ (2.13m) in all cases.
•
Do not place any combustible material within 4’ (1.2m) of the front of the unit.
• The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe.
•
The chimney connector must not pass through an attic or roof space, closet or similar concealed space, a
floor, or a ceiling.
•
For Canadian installations, where passage through a wall, or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365.
• A flue pipe crossing a combustible wall must have a minimum clearance of 18” (457.2mm).
• To reduce flue clearances from combustible materials, contact your local safety department.
Dimension
Inch
mm
A
Backwall to Stove
16
406
B
Sidewall to Stove
18
457
C
Wall to corner (Angled
Installation)
12
305
D
Backwall to Flue
21.5
546
E
Sidewall to Flue
30
762
F
Wall to Flue (Angled Installation)
24
610