Combustible:

Coal

Colors:

Black

Flue Pipe Diameter:

6” (153 mm)

Flue Pipe Type: 

Black or Blued Steel 2100°F (650°C)

Minimum Chimney Height:

12’ (3.7 m)

Dimensions
Overall: Depth x Width x Height:

22-3/16” (564 mm) X 33-11/16” (856 mm) X 34-3/16” (868 mm)

Combustion Chamber: Width x Depth: 22-1/8” (563 mm) X 13” (331 mm)
Door Opening: Width x Height:

10” (254 mm) X 13-1/5” (343 mm)

CAUTIONS:

•  HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY 

CAUSE SKIN BURNS.

•  DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
•  DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
•  DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
•  DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
•  ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
•  YOUR CHIMNEY MUST BE INSPECTED PRIOR TO THE INSTALLATION OF YOUR NEW COAL 

STOVE.  IN ADDITION, YOU SHOULD HAVE YOUR CHIMNEY INSPECTED FOR CREOSOTE DEPOSTS 

MONTHLY DURING THE HEATING SEASON AND ANNUALLY INSPECTED AND CLEANED.

For Customer Service, please 

call:
1-800-750-2723 Ext 5050 or;
Text to 423-301-5624 or;
Email us at:
customerservice@usstove.com

Note:

 Register your product online 

at 

www.usstove.com

 or download 

the free app today. This app is 
available only on the App Store for 
iPhone and iPad. Search US Stove. 
Save your receipt with your records 
for any claims.

INTRODUCTION

Summary of Contents for BCAC

Page 1: ...irements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Reference CALIFORNIA PROPOSITION 65 WARNING This product can e...

Page 2: ...N THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM ALWAYS CLOSE THE DOOR AFTER THE IGNITION YOUR CHIMNEY MUST BE INSPECTED PRIOR TO THE INSTALLATION OF YOUR NEW COAL STOVE IN ADDITION YOU SHOULD HAVE YOUR CHIMNEY INSPECTED FOR CREOSOTE DEPOSTS MONTHLY DURING THE HEATING SEASON AND ANNUALLY IN...

Page 3: ... Brand___________________________________ If no Date of inspection of existing venting system _______________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this manual...

Page 4: ...should check with local building officials to assure compliance with local regulations and codes HOW THIS HEATER OPERATES The chimney draft draws in combustion air through an adjustable air inlet thermostat located inside the cabinet Air flows through and across the bed of fuel causing the fire to progress through the fuel bed Heat is transferred to the air that flows between the cabinet and the f...

Page 5: ...STIBLE WALLS AND CEILINGS section of this manual for details FLOOR PROTECTION This heater must have a non combustible floor protector with a minimum type 1 ember protection extending beneath the heater if the floor is constructed of combustible material If a floor pad is used it should be UL listed or equal The floor protector should be large enough to extend under the stove and beyond each side a...

Page 6: ...rature Type HT Factory Built Residential and Building Heating Appliance Chimney is used follow the chimney manufacturer s installation instructions carefully If a masonry chimney is to be used be sure it is constructed to the National Fire Protection Association N F P A and local code standards The Chimney connector pipe from heater to chimney must be 6 in diameter and made from 24 gauge or heavie...

Page 7: ...ace 2 Use a solid insulated listed factory built chimney UL 103 HT length having an inside diameter of 6 and having 1 or more of solid insulation There must be at least a 9 air space between the outer wall of the chimney length and any combustible materials The inner end of the chimney length shall be flush with the inside of the masonry chimney flue shall be sealed to the flue and to the brick ma...

Page 8: ...s 3 and 4 connections to facilitate removal of the chimney connector for cleaning The chimney thimble shall be of ASTM C315 fireclay with 5 8 minimum wall thickness or material or equivalent durability The inside diameter of the thimble shall be sized for the proper snug fit of a 6 diameter chimney connector pipe The thimble shall be installed withoutdamagetothechimneyflue Thethimble shall extend ...

Page 9: ...onnector through a combustible wall for a connection to a masonry chimney Connecting Heater s Chimney Connector to Masonry Chimney When Chimney Connector Does Not Have to Pass Through a Combustible Wall CORRECT CONNECTION OF CHIMNEY CONNECTOR TO MASONRY CHIMNEY INSERT CHIMNEY CONNECTOR TO INSIDE FACE OF MASONRY CHIMNEY S FLUE LINER CHIMNEY THIMBLE INSIDE FACE OF FLUE LINER INCORRECT CONNECTION CHI...

Page 10: ...e be openings at the top and bottom of these clearance reducers so cool air can enter at the bottom and warm air exit at the top It is the chimney effect whereby when the air in the space is heated it rises exiting from the top and being replaced by cooler air at the bottom that makes these shields effective Masonry or other noncombustible products attached directly to a combustible surface withou...

Page 11: ...inch diameter holes at the points marked by step 6 8 Apply furnace cement to the inside surface of the heater s flue collar reinstall the first pipe or elbow and fasten in place with No 8 sheet metal screws Apply additional furnace cement to the outside of the chimney connector flue collar joint if an airtight seal was not achieved when the pipe or elbow was installed 9 Assemble the remaining chim...

Page 12: ...the fire will suffocate smoke and then die out NOTE Softwoods make better kindling than hardwoods because softwoods burn faster than the hardwoods NOTE If the heater tends to smoke when first lit a draft may be induced by holding a torch of rolled up newspaper at the opening of the flue collar Occasionally this must be done two or three times to establish an updraft before proceeding to the follow...

Page 13: ... TIME WHEN FRESH COAL IS ADDED ALWAYS LEAVE SOME OF THE GLOWING COALS UNCOVERED NEVER FILL THE HEATER SO THAT THE BURNING COAL IS ABOVE THE TOP OF THE HEATER S CHAMBER LINERS THIS WILL CAUSE THE HEATER TO OVERHEAT AND WILL SHORTEN ITS LIFE 9 MAKE SURE THAT THE HEATER S FUEL FEED DOOR ASH REMOVAL DOOR AND CABINET DOOR ARE SECURELY CLOSED 10 Set the heater s thermostat control knob to a point midway...

Page 14: ...e enough to break apart poorly connected chimney connector pipes If backpuffing is experienced see TROUBLESHOOTING section of this manual Backpuffing is an abnormal condition and a potential hazard Determine and correct the cause 5 TURN THERMOSTAT TO HI FOR 15 MINUTES AFTER ADDING FRESH COAL TO A FIRE This allows the gases to be driven off and shortens the length of time the dense smoke is likely ...

Page 15: ...good as anthracite Bituminous breaks up more in storage and burns with more smoke than does anthracite One other characteristic of bituminous which differentiates it from anthracite is that as the coal burns it tends to form clinkers whereas anthracite is reduced mainly to ash Clinkers are the misshapen rough gray lumps that form when particles in the coal are heated melt and fuse together When bi...

Page 16: ...ALS PENDING FINAL DISPOSAL IF THE ASHES ARE DISPOSED OF BY BURIAL IN SOIL OR OTHERWISE LOCALLY DISPERSED THEY SHOULD BE RETAINED IN THE CLOSED CONTAINER UNTIL ALL CINDERS HAVE THOROUGHLY COOLED Ashes should never be placed in wooden or plastic containers or in paper or plastic bags no matter how long the fire has been out Coals have been known to stay hot for several days when embedded in ashes VE...

Page 17: ... draft is sufficient air will be drawn into the heater through its thermostatically controlled inlet air damper This air supplies the oxygen necessary for the coal to burn If the draft is not sufficient insufficient oxygen will reach the burning fuel and it will burn poorly This condition can also cause smoke and dangerous gases to spill or backpuff from the heater into the room Backpuffing occurs...

Page 18: ...uctions that could be causing resistance to the flow of smoke and gases up the chimney 8 Check the size of the chimney flue liner If the chimney flue liner s inside dimension is smaller that 6 inches round or 8 inches square it will be too restrictive to the flow of smoke and gases A chimney flue liner which has an inside cross sectional area of more that 85 square inches is too large which will r...

Page 19: ...s gases and pressurized containers away from heater 7 Do complete the installation before attempting to use the heater 8 Do use only the prescribed materials and parts for the installation of the heater 9 Do install the heater in an area that will minimize the hazards of persons coming in contact with the hot surfaces of the heater 10 Do instruct all responsible persons in the proper and safe oper...

Page 20: ...eel pipe less than 24 gauge or pipe of a diameter smaller than 6 inches as a chimney connector 6 Don t store ashes in combustible containers not store them near combustible materials nor dispose of them until they have completely cooled 7 Don t use power blowers or air circulation systems with this heater that are not specifically recommended in this manual 8 Don t neglect to inspect regularly and...

Page 21: ... 2021 United States Stove Company 21 PARTS DIAGRAM ...

Page 22: ...ch Long 1 34 24837 Hinge Kit Feed Door 1 36 24838 Hinge Kit Ash Door 1 37 25048 Latch Kit For Ash Door 1 38 Refer To Item 32 39 69208 Ash Door Rope Assy 1 40 89930 Handle Kit 2 42 24828 Radiation Shield Kit 1 43 40412 Front Liner 1 45 89142 Knob Thermostat 1 46 851397 Control Plate 1 M 851728 Control Plate 47 24849 Rod And Nut Assy 1 48 69224GO Trim And Screen Assy 1 49 24851 Left Right Top Brace ...

Page 23: ...07 Date ______________________ Engineer Name ________________________________ License No _____________________________________ Company ______________________________________ Telephone No __________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date ______________________ Engineer Name ________________________________ License No ___...

Page 24: ...24 2021 United States Stove Company NOTES ...

Reviews: