Control Panel Overview
Turning the heater “On/Off”, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing
the appropriate button(s) on the control panel which is located on the lower left-hand side of your heater.
ON/OFF
Pressing the “On” button on the control panel will begin
the start-up sequence for the heater. Fuel will begin to
feed through the auger feed system then ignite after
approximately 5 minutes. Pressing the “Off” button on the
control panel will cause the heater to enter its shut-down
sequence. The fuel feed system will stop pulling fuel from the
hopper and, once the fire goes out and the heater cools
down, the fans will stop running.
HEAT RANGE
Pressing the “Heat Range” arrows, up or down, will adjust the
amount of fuel being delivered to the burnpot.
DRAFT FAN
The draft fan (exhaust) will come on as soon as the “On”
button is pressed. The fan will automatically adjust its speed in
accordance to the heat range setting. However, this speed
can be manually operated by pressing the “Draft Fan”
arrows up or down. “Draft Fan” when pressed, the display
will show “Df-A”, which is automatic. Press the arrows again
to adjust fan speed. When the heater is in the manual mode,
the optional thermostat will not properly control the unit.
When adjusting the draft fan setting, try only 1 setting above
or below the heat setting. It is better to leave the stove in the
automatic mode.
ROOM FAN
The room fan will come on once the unit has reached
operating temperature. By pressing the “Room Fan” buttons,
the display will show “Rf-A” which is automatic or “Rf-1”
through “Rf-9” for manual settings. In auto mode, the room
fan’s speed will automatically be adjusted in accordance
with the heat range setting. By pressing the “Room Fan” up
arrow, you can adjust the fan speed setting up to “Rf-9”. The
room fan must operate at a level greater than or equal to
the heat range setting.
AUX - USED TO RETURN THE STOVE TO THE FACTORY SETTINGS
To return the stove to it’s original factory settings, press and
hold the “Aux Up” and “Aux Down” buttons simultaneously
for 3 seconds.
AUGER DELAY
The “Auger Delay” button can be used to pause rotation of
the Auger for approximately 1 minute. This can be cancelled
by pressing the “On” button. The “Auger Delay” is normally
used only during the start up cycle to slow the fuel delivery
down during the initial ignition.
MODE - The “Mode” button is not used on this model.
During normal operation, the unit is constantly monitored
for problems. In the event of an error condition, the unit will
stop and an error will be displayed. See the list of error codes
found at the end of this manual.