ASI DOORS, INC.
(800) 558-7068
asidoors.com
18
Routing Sensor Wires
INS
TALL
ATION
Refer to figures 34 – 35 for wire routing for the 209 door light curtains or photo eyes
Leads from the light curtain or photo eye sensors come out at the top ends of the face frames or covers and need to
be routed up through the pocket in the extrusion and out to the control box
There are 4 possible routings for sensors depending on whether they are in the face frames, or covers, and whether
they are on the drive or idler side of the door All leads need to be routed to the control box which is normally
mounted on the drive side of the door
For sensors on idler side, leads will be routed through slots & holes in the header end plate and through the top rear
spreader bar, across to the drive side of door There should be a length of string routed through the top rear spreader
bar to aid you in routing cables through it Tie the string to the cables to be routed and pull them through the
spreader bar from the other side of the header
Drive side face frame sen-
sor wires Routed through
hole in top of header end
plate
Cables routed down to
control box
Drive Side Cover sensor
wires. Routed through
slot in bottom of Header
End Plate.
Idler side face frame sensor wires Routed
through hole in top of header end plate,
back through hole in center of top rear
spreader bar, and over to the drive side of
the door
Idler side cover sensor wires
Routed through slot in bottom of
header end plate, through hole in
center of top rear cross tube, and
over to drive side of door
Figure 34: Routing Sensor Wires