ASI DOORS, INC.
(800) 558-7068
asidoors.com
45
Error Codes
Continued
Code
Description
Cause
Corrective Action
E01
Slip error (Low Priority)
Mechanical overload
(Slip Monitoring) or
missing signal from
encoder
Check door for obstruction Ensure the pulse
output from the encoder is connected to terminal P2
on the controller Verify that the encoder pulse output
is set correctly
E02
Direction Error – occurs
during setup only (Low
Priority)
The direction of the
motor is incorrect The
encoder count must
increment positively
while the door is
moving in the open
direction
Use the Motor Direction parameter to set the
correct direction for the motor and encoder If the
motor moves in the incorrect direction and the encod-
er is decrementing, set the motor direction parameter
to Motor REV If the motor moves in the correct direc-
tion but the encoder is decrementing, set the Motor
Direction parameter to Encoder REV If the motor is
moving in the incorrect direction and the encoder is
incrementing, then set the motor direction parameter
to both REV
E03
No Signal From Pulse
Generator – occurs
during setup only (Low
Priority)
No pulse input
detected from the
encoder
Check door for obstruction Ensure the pulse output
from the encoder is connected to terminal P2 on the
Controller Verify that the encoder pulse output is set
correctly
E04
N/A
N/A
N/A
E05
Reference Switch
Connection (Medium
Priority)
The reference switch is
shorted or broken
Check the reference switch for damage and bad con-
nections Ensure the correct setting for the Reference
parameter Perform a quick setup to reset the position
limits
E06
Reference Switch False
Activation (Medium
Priority)
The reference switch was
activated in the wrong
position
Check the reference switch for damage and bad con-
nections Ensure the correct setting for the reference
parameter Perform a quick setup to reset the position
limits
E07
Run Timer Exceeded (Low
Priority)
The run timer has
expired
Check the run timer parameter to ensure a correct
value
E08
Safety Edge Test Fail
(Medium Priority)
The reversing edge test
has failed
Check the connections from the reversing edge to the
controller If using the SeyWave wireless system, check
operation of connected host and remote door sensor
Table 06 - Door Control Error codes