Surface-mounted Automatic hand dryer
General safety information
Installation
2
-- N
OTE: Do not install dryer over washbasin
--
Operating Instructions and Parts Manual
Hand Dryer
Disconnect power at the
source before installing or servicing.
This product is intended
for installation by a qualified service person.
All units must be supplied
with a 3-wire service. The ground wire must
be connected to the dryer's backplate.
Failure to properly ground
unit could result in severe electrical shock
and/or death.
1. Make sure the power source is switched off. Installation must be carried out in accordance with
the current edition of the local wiring regulations code having jurisdiction. Installation should be
performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at knockout (KO) location.
Note:
For two or more dryers, dryers should be no closer than 24 inches (610 mm) on center.
3. Remove and retain 2 cover screws and cover.
4.
For in-wall (concealed) power supply -
Provide supply wire to KO location according to local code
and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use 1/4 inch (M6) screws at length that will ensure 1 inch
(25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for 1/4 inch
(M6) screws to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to
ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal
block where indicated and connect ground wire to base plate with ground screw (Connections: A.
Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the
neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the
terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare
conductor) to the terminal block marked " " or to the green screw marked " "). Colors of live and
neutral wires depend on voltage of supply service and requirements of Building and Electrical Code
having jurisdiction.
7. Replace cover. Do not over-tighten screws.
www.asijdmacdonald.com.au
1800 023 441
A S I J D M a c D o n a l d P t y. L t d .
www.asijdmacdonald.com.au
Packing List
Quantity
Self-Threading Screws
4
Plastic Expansion
anchor
4
Dryer
1
Security hex wrench
Manual
1
1
Mounting template
1
Power cord
1