Surface-mounted Automatic hand dryer 

General safety information

Installation

2

-- N

OTE: Do not install dryer over washbasin  

--

Operating Instructions and Parts Manual 

Hand Dryer

                                Disconnect power at the
source before installing or servicing. 

 

                                

                                This product is intended 
for installation by a qualified service person. 

                                All units must be supplied 
with a 3-wire service. The ground wire must 
be connected to the dryer's backplate. 

                                Failure to properly ground 
unit could result in severe electrical shock 
and/or death.

1. Make sure the power source is switched off. Installation must be carried out in accordance with 
    the current edition of the local wiring regulations code having jurisdiction. Installation should be 
    performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark 
    locations of 4 mounting holes and wire service entry at knockout (KO) location.
    

Note: 

For two or more dryers,  dryers should be no closer than 24 inches (610 mm) on center.  

3. Remove and retain 2 cover screws and cover.
4. 

For in-wall (concealed) power supply - 

Provide supply wire to KO location according to local code 

    and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use 1/4 inch (M6) screws at length that will ensure 1 inch 
    (25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for 1/4 inch 
    (M6) screws  to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to 
    ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal 
    block where indicated and connect ground wire to base plate with ground screw (Connections: A. 
    Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the 
    neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the 
    terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare 
    conductor) to the terminal block marked "    " or to the green screw marked "    "). Colors of live and 
    neutral wires depend on voltage of supply service and requirements of Building and Electrical Code 
    having jurisdiction.
7. Replace cover. Do not over-tighten screws. 

 

 

www.asijdmacdonald.com.au  

1800 023 441  

A S I J D M a c D o n a l d P t y. L t d .

www.asijdmacdonald.com.au

Packing List

Quantity

Self-Threading Screws

4

Plastic Expansion 

anchor

4

Dryer

1

Security hex wrench

Manual

1

1

 Mounting template

1

Power cord

1

Summary of Contents for AUTOBEAM

Page 1: ...7 0kg 15 4lbs 300mm W x 251mm H x 219mm D 11 13 16 x 9 7 8 x 8 5 8 2200W 220 240VAC nichrome 27 2Ω 100mm to 250mm 4 to 10 adjustable standard 170mm 20mm 7 www asijdmacdonald com au Auto resetting thermostat turns unit off at 65 C 149 F resets at 50 C 122 F HDABWHTSG white with silver gloss nozzle HDABWHTPC white with polished chrome nozzle HDABPSSPC polished stainless steel with polished chrome no...

Page 2: ...rely to chassis at KO with appropriate strain relief connector not supplied 5 Attach dryer to wall For wood wall studs use 1 4 inch M6 screws at length that will ensure 1 inch 25 mm min stud penetration For masonry walls use expansion bolts or anchors for 1 4 inch M6 screws to ensure penetration 1 4 inch 6 mm deeper than anchor Shim if necessary to ensure base plate is flat against wall 6 Connect ...

Page 3: ...dren 4 7 years Children 8 10 years Children 11 13 years Children 14 16 years 50 1194 mm 47 889 mm 35 991 mm 39 1092 mm 43 1194 mm 47 Surface mounted Automatic hand dryer Circuit Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au Circuit Board Module MO2 HE2 N MO1 HE1 L Transistor Power Switch G N L Thermostat G Y Blue Brown Motor With Thermal Switch 2A Black 120 240V Black 12...

Page 4: ...oose or damaged wires Remove the blower housing Check the element for signs of burning or breakage Damaged element must be replaced If the element does not appear damaged disconnect it at the timer assembly and check element wire continuity see tech spec An open circuit indicates damage to the element wire and to the integral temperature limit control TLC Separate the TLC and test for open circuit...

Page 5: ...housing RH Thermostat TLC Motor bracket Nylon washer Motor Motor 200W 240Vac Motor brush Rubber grommet Motor Rating label 220 240Vac Terminal label Screw M4x6 headless set with 2mm hex key Screw 10 24x1 2 philips truss head Hex Nut 10 24 Self Threading Screw M4x10 philips pan head 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A0183 A0131 A0065 A0066 A0068 A0069 A0071 A0072 A0277 A0288 Screw M5x10 ...

Page 6: ...urface mounted Automatic hand dryer 1 2 3 4 5 Assembly Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au 6 7 8 9 11 12 23 34 13 14 15 16 17 18 19 20 21 22 36 24 25 26 27 28 29 31 32 33 35 37 38 39 40 41 42 10 ASI JD MacDonald Pty Ltd ...