background image

4

www.americanspecialties.com

Diagnostics and Remedies

I

f the dryer will not run

The dryer cycles by itself
or runs constantly

The  dryer  runs  but  air
stream is low pressure
and/or low velocity

Ensure that there is no obstruction on or in front of the IR sensor. Clean
any dirt or debris off the sensor lens. If problem persists, replace sensor.

First ensure that the breaker supplying the dryer is operational. If it is,
disconnect  the  power  and  remove  the  dryer  cover.  Taking  suitable
precautions to avoid shock hazard, reconnect the power and check for
Voltage at the terminal block. Verify that connections are made correctly.

Ensure that the supply Voltage is correct.  Dryer will run weakly if the
input Voltage is too low.  Verify Voltage requirement on unit rating label
and correct supply as required.

The dryer makes a loud
noise and does not run
for a complete cycle

Ensure that the supply Voltage is correct. Dryer will make a loud humming
noise if the input Voltage is too high. Verify Voltage requirement on unit
rating label and correct supply as required. If CBM has been damaged,
replace CBM, IR sensor module.

Symptom                                                                 

Corrective Actions for Initial Installation Failures

Symptom                                                                 

Corrective Actions for In-Service Failures

I

f the dryer will not run

The IR sensor only “sees”
close range objects

The dryer only blows cold
air during a full cycle

Ensure that there is no obstruction on or in front of the IR sensor. Clean
any dirt or debris off the sensor lens. If problem persists, disconnect the
power and remove the dryer cover and replace CBM, IR sensor module.

First  ensure  that  the  breaker  supplying  the  dryer  is  operational.  If  it  is,
disconnect  the  power  and  remove  the  dryer  cover.  Replace  the  CBM
and  IR  sensor  module.  Taking  suitable  precautions  to  avoid  shock 
hazard, reconnect the power and check for Voltage at the terminal block.

Disconnect the power. Remove the dryer cover and check/ ensure heater 
SW is ON. Disassemble the blower-motor/fan housing. Test the thermostat 
for open circuit. Check the heater element for signs of burning or breakage. 
Damaged element must

 

be replaced.

The  heater  gets  hot  but
no air stream is produced

Disconnect  the  power.  Remove  the  dryer  cover.  Check  VR  for  speed 
setting Disassemble the

 

blower- motor/ fan housing. Replace the fan motor.

Reassemble.

The  air  stream  is  low
pressure and velocity

Check the output nozzle for obstructions. If none are present, disconnect
the  power.  Remove  the  dryer  cover.  Remove  any  dust/lint  buildup  from 
intake  vent  slots.  Check  VR  for  speed  setting.  Disassemble  the  blower-
motor/fan housing. Check the motor brushes for worn condition (

 1-3/16” 

[30 mm] graphite remains) and replace them, if necessary.

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted 

ADA

-compliant hand dr yer 

General safety information:

                                Disconnect power at the
service breaker before installing or servicing. 

 

                                

                                This product is intended 
for installation by a qualified service person. 
Use AWG NO. 12 solid conductor for wiring.

                                All units must be supplied 
with a 3-wire service. The ground wire must 
be connected to the dryer's backplate. 

                                Failure to properly ground 
unit could result in severe electrical shock 
and/or death.

1207131423 Rev C 3 October. 2013

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

Reviews: