PURE Aquarium KIT

4.3.  Assembly

CAUTION

To prevent the risk of scratching the product: clean 
it exclusively using a soft cloth moistened with water. 
Do not use abrasive products, toxic substances or de-
tergents.

1)  Clean the tank with a cloth moistened with water (fig. 6).
2)  Install the thermal heater with its provided bracket (fig. 7)IM-

PORTANT: For proper installation, make sure the adjustment 
knob is below the bottom edge of the decorative trim. Place 
the thermal heater in the aquarium and press its suction caps 
against the wall so that they adhere. Set the desired water tem-
perature using the adjustment knob referred to the graduated 
scale in °C 

(fig. 8).

3)  Restore the frame to the tank.
4)  Unwind the thermal heater cable and route it out of the tank via 

the pump compartment 

(fig. 9).

5)  Restore the pump in its compartment, tidy away the thermal 

heater power cable 

(fig. 10).

6)  Pick the baskets for the mechanical filtration sponges. Take out 

the sponges, rinse them under running water and replace them 
in the baskets 

(fig. 11).

7)  Pick the biological baskets with their cover (fig. 12).
8)  
Take the ceramic cylinders, one CARBON cartridge and one 

ZEO cartridge.

9)  On a washbasin, open the bags containing the ceramic cylin-

ders, then pour them into the biological baskets and rinse them 
under running water; rinse also the CARBON and ZEO cartridg-
es after having extracted them from the bag 

(fig. 13).

10)  Reposition the biological baskets, the basket for the mechanical 

filtration sponges, and the CARBON and ZEO cartridges in the 
proper frame spaces 

(fig. 14).

11)  Dispose of the plastic bags in observance of local regulations.
12)  Restore the light cover to the frame after removing the sticker 

securing its power cable 

(fig. 15).

13)  Route the power cables for the three electrical devices (lighting 

unit, pump unit and thermal heater) out of the tank through the 
fairlead seat 

(fig. 16).

14)  Restore the filter cover to the frame and hook up the lighting unit 

to the led driver with its connector 

(fig. 17).

15)  Gather all cables into the provided cable guide (fig. 18).

4.4.  Installation

WARNING

Do not connect the electric devices of the product to 
the mains before having completed the installation. Do 
not use the thermal heater and the pump dry.
After installation, do not move the product.
If necessary, move it only if the tank is completely 
empty.

CAUTION

When choosing the suitable setup for your aquarium, follow the 
advice of a qualified retailer.

Make sure that the equipment material or any other 
objects present in the tank do not obstruct the inlet 
grids placed at the lower end of the intake tube.

Do not lean any heavy objects on the intake tube.

After installation, check the correct water level.

1)  Open the light cover and slowly fill the tank with water until it 

reaches a level included between the min. and max. levels, as 
shown on the label inside the tank 

(fig. 19).

2)  Close the light cover and check the tank for leaks.

5. STARTING UP THE SYSTEM

5.1.  Routine operation

WARNING

To avoid electric risk, each power cable of the electric 
devices has to show a drip loop positioned lower than 
the plug-outlet connection point in order to prevent any 
drop from reaching such point.

1)  Read the warnings in Chap. 1.
2)  After having connected the plug of each electric device verify the 

operation of the same (in case of malfunction refer to 

(in case of malfunction refer to 

chap. 7

chap. 7):):

• Water should flow out of the delivery.
• The warning light of the thermal heater should turn on if the 

water temperature is lower than the setpoint.

• The programming timer should be on, with its two first digits 

flashing.

5.1.1. Programming the timer and lighting system

PURE XL HC

 LED

 MARINE aquariums are equipped with an integrat-

ed digital electronic timer that controls the switching-on sequence of 
the white, red and blue LEDs that make up the lighting unit. Thanks 
to a simple interface (fig. 20), the timer allows performing several 
functions:
•  Light on / off in manual mode.
•  Light on / off in automatic mode, at set times.
•  Managing the Rolling Filtration Timer (RFT), the system that 

every 15 days reminds the user to replace the CARBON and 
ZEO cartridges to keep the aquarium under ideal conditions.

The timer has three touch sensitive buttons, 4 status icons and 4 
digital digits. If you set automatic light on/off times, the unit runs a 
daily cycle with the following steps:
1)  Switching-on of the blue actinic light 2 hours before the switch-

ing-ON time set by the user, with a progressive raising of the 
light intensity for about 30 minutes (only the blue LEDs are on).

Summary of Contents for PURE XL HC LED

Page 1: ...PUREXL HC LED MARINE AQUARIUM KIT Instruction manual Manuale di istruzioni Manuel d instructions Bedienungsanleitung Handleiding EASYAQUARIUM PURE MARINE...

Page 2: ...sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved...

Page 3: ...ith a sensitivity 30 mA After maintenance operations if necessary dry the external parts of the product and the stand To protect the polished surfaces of the product from scratches and scrapes pay utm...

Page 4: ...the components shown in the following figures 9 10 8 11 PURE MARINE PURE MARINE 1 2 3 4 5 6 7 1 Glass tank 2 2 Edge seals glass sealant Edge seals glass sealant 3 Light cover door 4 Light cover 5 Filt...

Page 5: ...tube 23 Impeller 24 Pump gasket 25 Pump motor 26 Delivery water outlet nozzle 27 Accessories compartment 28 Chemical cartridges in bag 2 CARBON cartridg es and 2 ZEO cartridges 29 Ceramic cylinders in...

Page 6: ...from the tank fig 5 and place it on a flat clean surface without scratching it 8 Carefully remove the thermal heater and led driver from their packaging inside the tank along with the cable guide 9 Di...

Page 7: ...tallation Do not use the thermal heater and the pump dry After installation do not move the product If necessary move it only if the tank is completely empty CAUTION When choosing the suitable setup f...

Page 8: ...9 EN 6 7 3 0 1 9 2 2 24 2 7 8 9 10 11 12 13 14 15 16 17 18 max min PURE 19 20...

Page 9: ...programming operation is carried out the lighting system is pre set to switch the day light on at 10 00 a m and switch it off at 6 00 p m according to pre set ramps Therefore the blue light will swit...

Page 10: ...and limiting the build up of nitrates The regular replacement of the CARBON and ZEO cartridges par 6 2 allows keeping the main unwanted compounds under control thus maintaining the water clear and cr...

Page 11: ...s of parts affected by the salt condensate To remove the salt scaling that is most difficult to clean mere lemon juice can be used Then rinse thoroughly to remove any acid residues 6 1 Maintenance and...

Page 12: ...If the light cover or the lighting unit with the timer need re placing disassemble the two elements by unscrewing the three screws which keep them together using a suitable Phillips screwdriver fig 26...

Page 13: ...50102 UK AB350103 Lighting unit with timer 10 AB350104 Thermal heater THERM 13 14 EUR AA230004 UK AA230009 Heater bracket with suction cups 14 AB230001 Delivery and intake KIT 19 22 26 AB350101 Basket...

Page 14: ...E1642201 16M17 Askoll Due S r l Via Industria 32 34 36031 DUEVILLE VI ITALIA www askoll com PURE MARINE...

Reviews: