Installation of the ASL 102 UNO Bluetooth Single Switch Scanner and the programming of the wheelchair
electronics should only be conducted by a specialist with an in depth technical knowledge of the ASL 102 UNO
Bluetooth Single Switch Scanner and the wheelchair electronics. All testing and verification of the completed
wheelchair equipment with the ASL 102 UNO Bluetooth Single Switch Scanner to ISO/RESNA or applicable
standards for the completed wheelchair, including RFI compatibility testing, is the sole responsibility of the
wheelchair manufacturer.
The ASL 102 UNO Bluetooth Single Switch Scanner is warranted to be free from manufac turing
defec ts for two years from date of purchase.
WARRANTY
This warranty shall not cover equipment modified or repaired by unauthorized personnel. ASL cannot be held responsible for damage
caused by incorrect installation or incorrect use of the product. Misuse, mishandling, or storage is not covered by this warranty. The
foregoing express warranty is exclusive and in lieu of any other warranties of any kind, whether express or implied, including the implied
warranties of merchantability or fitness for a particular purpose, and is the sole and exclusive remedy for any defective product. The health
care professional is responsible for understanding the intended use of the ASL equipment and the specification and safe programming
parameters of the chair it is going on. The wheelchair manufacturer is responsible for testing and verification of the completed wheelchair
equipped with the ASL 102 UNO Bluetooth Single Switch Scanner to ISO, RESNA or other applicable standards including RFI compatibility.
RFI interference can impact the proper functioning of the wheelchair. Route and secure all cables in such a way in order to prevent
damage by crushing, cutting or snagging. Incorrect installation, configuration, or programming could result in unsafe set up of the
wheelchair for the user. ASL accepts no liability for losses of any kind which result for such conditions.
ATOM
Technology
Powered by
102 UNO FULL ASSEMBLY
UNO ACCESSORIES
ASL 557-3 ATOM Bluetooth Wireless Switch Receiver
The ASL 557-3 ATOM Bluetooth Wireless Switch Receiver is intended to be used for
Bluetooth wireless access to communication devices, TECLA Shield, TECLA E, or switch
inter faces on a computer. The USB side plugs into a communication device directly, or into
a computer. Each plug corresponds to the pad on the head array (for ward, right, or left).
You can connect the plugs to the scan and select por ts of a communication device, switch
inter face or TECLA por ts. If using with the TECLA products, you need a rechargeable batter y.
ASL 545E Tecla - Bluetooth Interface
Tecla is a cloud connected assistive device that provides users with control of their smar t
device and enviroment. Using Bluetooth, Tecla connects directly to ATOM technology whenever
the ATOM is in wireless mode. ATOM technology speaks directly to the Tecla which is able
to connect up to 8 devices. You can use Tecla with iPhone, iPad, iPad Touch, Mac computers
with switch control, Apple TV’s with switch control, Android devices with switch access,
Samsung devices with universal switch and Windows computers with scanning software.
ASL 102 UNO BLUETOOTH SINGLE SWITCH SCANNER
Adaptive Switch Laboratories, Inc. www.asl-inc.com PH: 800-626-8698, FX: 830-798-6221 Rev 5-2020
Adaptive Switch Laboratories, Inc. www.asl-inc.com
SCAN FOR PROGRAMMING
INFORMATION
SECURITY MEASURES
A reset switch should always be plugged into a reset por t programmed to stop the chair and be available
in case of emergenc y to stop movement of the wheelchair. The ASL 102 UNO Bluetooth Single Switch
Scanner is susceptible to moisture. If moisture contac ts a sensor, unwanted movement may occur. Do
not operate the ASL 102 UNO Bluetooth Single Switch Scanner in rain or snow.
CONNECTION REQUIREMENTS:
LiNX Input Module
MK6i Digital Inter face
Omni or Omni 2
Enhanced Display or SCIM
UNO ATTENDANT CONTROL
UNO INTERFACE
UNO DISPLAY
WHEELCHAIR
CONNECTION
ASL 802/4 ECU Interface Cable
The ASL 802-4 ECU Inter face Cable – 4 Mono Plugs conver ts commands from the auxiliar y
por t into a mono input. It can be used for functions such as tilting or reclining the power
wheelchair, accessing a computer, a communication device, or anything that requires a mono
plug. The for ward mono jack plug is the activation for selection while in the auxiliar y mode.