Pressure Relief Procedure
Follow Pressure Relief Procedure when you
stop spraying and before cleaning, checking, servicing or transporting
equipment.
1.
Turn power switch OFF and unplug power cord.
Fig. 6
2.
Turn Spray–Prime/Drain valve to PRIME/DRAIN to
relieve pressure.
Fig. 7
PRIME
3.
Turn pressure to lowest setting. Hold metal part of
gun firmly to a grounded metal pail. Trigger gun to
relieve pressure.
Fig. 8
ti6912a
4.
Engage trigger lock.
Fig. 9
ti6763b
D
Leave Spray–Prime/Drain valve in PRIME/DRAIN
position until you are ready to spray again.
D
If you suspect the spray tip is clogged or that
pressure has not been fully relieved after following
the above steps, VERY SLOWLY loosen tip guard
retaining nut or hose end coupling to relieve pres-
sure gradually. Then loosen completely. Clear
hose or tip obstruction.