INDUS classic 74-312
Inductive signal transmission system
21
10
Taking out of service and disposal
The products manufactured by ASO are intended solely for commercial use (B2B) At the end of use,
the products are to be disposed of according to all local, regional and national regulations Products
can also be returned to ASO, which will then dispose of them properly
11
Technical specifications
Supply voltage
Mains voltage:
U
mains
230 V AC 50/60 Hz
Low voltage:
U
E
24 V AC/DC ±10 %
Power consumption
P
max
3 VA
Housing
Polystyrene with transparent cover
Dimensions
(HxWxD)
Housing
80 x 120 x 55 mm
Housing incl cable clamps
102 x 120 x 55 mm
Protection class
IP65
Weight
460 g
Temperature range
-20°C to +55°C
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
2
Certifications
DIN EN ISO 13849-1:2008 Category 3 PL e
MTTFd 170 years, DC 91%
Electronics
MTTFd 1616 years, DC 99 %
Electromechanics
B10d 1000000
MTTFd 190 years (Nop 52560)
Safety device acc to DIN EN 12978
All voltages connected to the switching unit must be safely
isolated!
Stationary
contact edge
Travelling
contact edge
nominal value
R
nom
= 8,2 kΩ
= 8,2 kΩ
upper switching point
R
AO
> 12 kΩ
> 20 kΩ
lower switching point
R
AU
< 5 kΩ
< 2,5 kΩ
Terminal resistance of the safety contact edges
Nominal current DC
2 A
24 V DC
Nominal current AC
2 A
30 V AC
Mech life-time
>10
6
actuations
Stationary
contact edge
Travelling
contact edge
Switching off delay (response time)
< 10 ms
< 30 ms
Switching on delay
500 ms (Power on 700 ms)
protection
2A time lag (glass tube 5x20)
Test report no.:
12 205 399386-000
Certificate no.:
44 780 12 399386
EC type-examination no.:
44 205 12 399386
80
102
120
55