NOTE: AHRS Flags may take up to 3 minutes to clear. Airspeed and Altitude flags may take up to 20
minutes to clear at temperatures below -20ºC.
10.4
System Configuration
Configure the EFD1000 E5 system prior to running the ground test procedure. The
configuration pages are accessed through the EFD display using the MENU button and the
lower Right Control Knob labeled MODE/SYNC.
10.4.1
Main Menu Access
Pushing the “MENU” button accesses the Main Menu operation. See E5 Pilot Guide for
Main Menu operation.
10.4.2
Menu Navigation
When no fields are enabled for editing, rotating the right control knob clockwise
advances to the next menu page and counterclockwise advances to a previous
menu page.
Editable menu items are displayed in white text on a blue background, non-editable
menus items are green text on a blue background while grey text on a blue background
is disabled from editing.
10.4.3
Edit Mode
Pushing the line select key adjacent to an editable field enables the associated field for
editing. The field turns magenta when enabled and the right control knob reads “Edit
Value”.
When the field is enabled for editing rotating the right control knob will adjust the value.
Pushing the right control knob or the adjacent line select key will exit from the editable
field.
10.4.4
Main Menu Configuration
The Main Menu consists of pages that are pilot selectable. Refer to the EFD1000 E5 Pilot
Guide for Main Menu configuration if necessary.
10.4.5
Installation Menu – Unit Configuration
The Installation Menu is entered from the Main Menu’s “SYSTEM STATUS PAGE” (last
page). Simultaneously push and hold the MENU key, Line Select Key #1 and Line Select
Key #2 for 3 seconds while the airspeed is below 30 units.