EFD1000 E5 Dual Electronic Flight Instrument (EFI) Install Manual
DOCUMENT # 900-00041-001
PAGE 83-226
REVISION D
© Copyright 2019 Aspen Avionics Inc.
Figure 7-2: RSM Connector assembly
CAUTION: Do not run RSM wiring near high current devices such as strobes and air conditioners and
avoid running RSM wiring in same wire bundle as strobe and air conditioning wiring
bundles if at all practical.
7.2.6.3
EFD END
Terminate the shield at the EFD end inside the back shell. Attach pigtail ground wire to
shield and connect to ground screw as shown in Figure 7-3.
Figure 7-3: EFD Back Shell Grounds/RSM
7.2.7
Configuration Module Wiring
The Configuration Module (CM) connector comes as an assembly with color-coded wires
within an over braid. The wires are inserted into the appropriate pins as shown in Figure
9-1. The green wire with ground lug is attached to back shell.
EFD Pin
Color
CM Pin
41
Black
1
42
Brown
2
43
Orange
4
44
Red
3
--
Green
5
Table 7-2: CM Wiring
Metal Clamper
Qty 7
– 22/24 AWG conductors
Screw
To
PFD
Hood
Metal
Cover
Connector
To
RSM
M27500-22TG7T14 or
M27500-A24SD7T23 or equivalent
Washer
Shield folded
back on jacket
Shield
Solder Splice or
solder then
Heat Shrink as required
To RSM
M27500-22TG7T14 or
M27500-A24SD7T23 or equivalent