EFD1000H PFD Pilot’s Guide
Page 6-14
091-00012-001 REV C
EFD1000H PFD Pilot’s Guide
Page 6-15
091-00012-001 REV C
CHAPTER 6
EXP
ANDED EMERGENC
Y AND ABNORMAL PROCEDURES
Perform an In-Flight AHRS Reset
1. Maintain straight and level flight.
2. Consider exiting IMC.
3. Fly by visual reference or by standby instruments.
4. Disconnect the autopilot.
5. Press the MENU Button.
6
Rotate the Right Knob to display the GENERAL SETTINGS A Menu page.
7. Press the AHRS RESET? Menu Key (
Figure 6-7
).
A confirmation message displays, prompting the user to confirm the reset
request (
Figure 6-8
).
8. Press the AHRS Menu Key again to confirm the AHRS reset. The AHRS reset is
performed, and the confirmation messages clears.
9. Press the MENU Button to exit.
Figure 6-7
AHRS Reset Menu Key
Figure 6-8
AHRS Reset Confirmation Message
NOTE
Pressing any other key, button, or knob cancels the
AHRS reset and clears the confirmation message.