6
If the door is left open for longer than a preset time, the keypad will generate an
alarm until the door is closed. The door open time can be programmed from 1 to
999 seconds. Door position is monitored via the
Door Position Sensor Input
.
1. Put the keypad in
Program Mode
by entering the
Installer Code
followed by
the “
”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “
9 (door open time 1-999) #
”.
3. Enter “
” to exit Program Mode. The yellow LED will begin blinking.
To disable the
Door Propped Open Alarm
feature -
1. Put the keypad in
Program Mode
by entering the
Installer Code
followed by
the “
”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “
9 0 #
”.
3. Enter “
” to exit Program Mode. The yellow LED will begin blinking.
Outputs 1 and 2 can be programmed for either momentary or latching operation.
Momentary operation time can be set for between 1 and 999 seconds. The
factory default momentary operation time is 2 seconds.
1. Put the keypad in
Program Mode
by entering the
Installer Code
followed by
the “
”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Output 1
Momentary Mode
-
Enter “
4 0 (output active time 1-999) #”
Output 2
Momentary Mode
-
Enter “
5 0 (output active time 1-999) #”
Output 1
Latching Mode
-
Enter “
4 1 #”
Output 2
Latching Mode
-
Enter “
5 1 #”
3. Enter “
” to exit Program Mode. The yellow LED will begin blinking.
To disable the
Door Forced Open Alarm
feature -
1. Put the keypad in
Program Mode
by entering the
Installer Code
followed by
the “
”. The keypad will beep twice and the yellow LED will be on and not
blinking.
2. Enter “
8 0 0 #
”.
3. Enter “
” to exit Program Mode. The yellow LED will begin blinking.