background image

 

KEYPAD SILENT MODE 

The keypad beeper can be silenced. 
1.  Put the keypad in 

Program Mode

 by entering the 

Installer Code 

followed by 

the “

”. The keypad will beep twice and the yellow LED will be on and not 

blinking. 

2. Enter “

8 3 0 #

”.  

3. Enter “

” to exit Program Mode. The yellow LED will begin blinking. 

To return the keypad to audible mode - 
1.  Put the keypad in 

Program Mode

 by entering the 

Installer Code 

followed by 

the “

”. The keypad will beep twice and the yellow LED will be on and not 

blinking. 

2. Enter “

8 3 1 #

”.  

3. Enter “

” to exit Program Mode. The yellow LED will begin blinking. 

When the keypad is programmed for 

Auto Entry Mode 

it is not necessary to 

terminate 

User Codes 

with the “

#

” during operation. However, in 

Auto Entry 

Mode

 the 

User Code 

must be the same length (4 to 8 digits) as the 

Installer 

Code

To put the keypad in 

Auto Entry Mode 

1.  Put the keypad in 

Program Mode

 by entering the 

Installer Code 

followed by 

the “

”. The keypad will beep twice and the yellow LED will be on and not 

blinking. 

2. Enter “

8 2 1 #

”.  

3. Enter “

” to exit Program Mode. The yellow LED will begin blinking. 

To return the keypad to 

Manual Entry Mode 

1.  Put the keypad in 

Program Mode

 by entering the 

Installer Code 

followed by 

the “

”. The keypad will beep twice and the yellow LED will be on and not 

blinking. 

2. Enter “

8 2 0 #

”.  

3. Enter “

” to exit 

Program Mode

. The yellow LED will begin blinking. 

AUTO OR MANUAL CODE ENTRY MODE 

The 

Duress Output 

is not a programmable feature. The keypad automatically 

creates a 

Duress Code 

based on 

User Codes

. The 

Duress Code

 is the 

User 

Code 

with the first digit increase by 2. For example: If a 

User Code 

is “1234” then 

the 

Duress Code 

is “3234”. There are no 

Duress Codes 

created for Output 2 

User Codes

When a 

Duress Code 

is entered, Output 1 will activate and the Duress Output 

will go to ground (-) and will not return to it’s normal state until a valid 

User Code 

is entered. 
The keypad does not allow 

User Codes 

to be duplicates of 

Duress Codes

. For 

example: If the 

User Code 

is “1234” then the 

Duress Code 

is “3234” and the 

keypad will not allow a 

User Code 

of “3234”. 

DURESS OUTPUT 

Summary of Contents for Alarm Controls KP-300

Page 1: ...00 645 5538 www alarmcontrols com Model KP 400 is a self contained vandal resistant digital keypad This dual relay output keypad is suitable for residential industrial and commercial installations It...

Page 2: ...ed tool 2 Pass the wire harness through the opening in the back box 3 Mount the back box to the door frame or wall 4 Make all required wiring connections to the terminal blocks 5 Place the keypad face...

Page 3: ...put that switches to ground after the duress code has been entered Output rating Ic max 100mA sink Vc max 24VDC Door Position Sensor Input DOOR SENS A normally closed contact connected to this termina...

Page 4: ...Programming Mode in order to access all keypad configuration settings 1 Put the keypad in Program Mode by entering the Installer Code followed by the The keypad will beep twice and the yellow LED wil...

Page 5: ...tering the Installer Code followed by the The keypad will beep twice and the yellow LED will be on and not blinking 2 Enter 7 2 5 3 Enter to exit Program Mode The yellow LED will begin blinking To dis...

Page 6: ...s 1 and 2 can be programmed for either momentary or latching operation Momentary operation time can be set for between 1 and 999 seconds The factory default momentary operation time is 2 seconds 1 Put...

Page 7: ...ep twice and the yellow LED will be on and not blinking 2 Enter 8 2 1 3 Enter to exit Program Mode The yellow LED will begin blinking To return the keypad to Manual Entry Mode 1 Put the keypad in Prog...

Page 8: ...new installer code For example if you wish to change the Installer Code to 1 2 3 4 you would enter 0 1 2 3 4 7 The keypad will beep twice indicating that the new Installer Code has been accepted 8 Ent...

Page 9: ...DC POWER SUPPLY AC POWER CAN ONLY BE USED WITH AC POWERED ELECTRIC STRIKES MAGNETIC LOCK OR ELECTRIC STRIKE MODEL TS 2 REQUEST TO EXIT STATION OPTIONAL USE N O CONTACTS Output 2 is used to control acc...

Page 10: ...2 REQUEST TO EXIT STATION OPTIONAL USE N O CONTACTS N C DOOR CONTACT Two keypads are required for an inter lock system If either door is open the other door will remain locked TAMPER SWITCH The Tampe...

Page 11: ...5 Relative Humidity Non condensing Environmental Rating Conforms to IP66 Dimensions 3 125 W x 4 5 L x 1 75 to 2 5 D CODES It is recommended that the Installer Code and User Codes be noted here for ref...

Page 12: ...KP 400 Rev E 3 14...

Reviews: