56
ARMED EXIT DELAY BEEPS TO KEYPAD
ARMED EXIT DELAY BEEPS TO KEYPAD -
P58E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8
When an Area is Armed it is useful to have the exit delay beeps occurring at the keypad to warn the User to exit the
premises without delay. If the option is on at this address, that keypad will beep out the exit delay. The exit beeps occur
at one second intervals until the last 5 seconds at which time they change to 1/2 second intervals to act as a warning that
the delay is about to expire.
STAY MODE EXIT DELAY BEEPS TO KEYPAD
STAY MODE EXIT DELAY BEEPS TO KEYPAD -
P59E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8
When an Area is Armed in Stay Mode it is useful to have the exit delay beeps occurring at the keypad to warn the User to
exit the premises without delay. If the option is on at this address, that keypad will beep out the exit delay. This option
may be turned off for Stay Mode to make the keypad silent when arming at night time. The exit beeps occur at one
second intervals until the last 5 seconds at which time they change to 1/2 second intervals to act as a warning that the
delay is about to expire. When arming Stay Mode the exit and entry delays can be cancelled by pressing the <ENTER>
button following arming of Stay Mode. The next time Stay Mode is armed, if the <ENTER> button is not pressed, all
programmed exit and entry delays will apply.
ARMED EXIT DELAY TIME
ARMED EXIT DELAY TIME -
P60E 1-2E (1 = Area A, 2 = Area B) (Value 0-255 Seconds)
Each Area can have their own exit delay time. The delay can be programmed from 1-255 seconds in one second
increments. If the exit delay is set to “0” the panel will be instantly armed.
STAY MODE EXIT DELAY TIME
STAY MODE EXIT DELAY TIME -
P61E 1-2E (1 = Area A, 2 = Area B) (Value 0-255 Seconds)
Each Stay Mode Area can have their own exit delay time. The delay can be programmed from 1-255 seconds in one
second increments. If the exit delay is set to “0” the panel will be instantly armed.
MONITORING ACCOUNT CODE NUMBER
MONITORING ACCOUNT CODE NUMBER -
P62E 1-2E (1 = Area A, 2 = Area B) (Value 0000-FFFF)
When the dialler is reporting to a monitoring station there must be a unique account code programmed to identify the
panel. There is an account code for each area. The account code is 4 digits. Each digit can be a number from 0-9 as well as
the special characters B,C,D,E & F. The chart below shows how the special characters are entered.
DTMF REMOTE CONTROL CODE NUMBER
DTMF REMOTE CODE NUMBER -
P63E 1-2E (1 = Area A, 2 = Area B) (Value 1-4 digit code 0-9999)
The panel can be configured to allow remote Arm/Disarm of each Area via a remote telephone. The codes programmed
at this address are the DTMF code that must be used when performing this function. When dialling the panel and it has
answered the call, after waiting for the panel modem tones to stop you can enter in the 4 digit DTMF code and the
current status will be given of the Area associated with the code entered. After that, if you press the “*” button on the
telephone the status of the area will toggle eg if is was previously armed it will change to disarmed or vice versa. When
finished you simply hang-up and 15 seconds later the panel will release the line.
Summary of Contents for Avolution S series
Page 119: ...119...