80
KEYPAD LISTEN-IN OPTIONS
KEYPAD LISTEN-IN OPTIONS -
P175E 6E
Option 1 - Listen-in Enabled when dialling only and in Disarmed State
Option 2 - Listen-in Enabled when dialling only and in Armed State
Option 3 - Listen-in Enabled when dialling only and in Monitor Mode
Option 4 - Listen-in Enabled through the entire call only in Disarmed state
Option 5 - Listen-in Enabled through the entire call only in Armed State
Option 6 - Listen-in Enabled through the entire call only in Monitor Mode
Option 7 - Listen-in Enabled when the panel answers a call
Option 8 - Listen-in on at All Times
The panel provides the facilities to use the buzzer in the keypad as a speaker to listen to the call being made by the
dialler. To use this feature a 5th wire must be connected between the panel and a keypad using the listen-in terminals.
The options above allow many combinations of the listen-in to be used or it can be disabled by selecting no options.
OUTPUT # 1 LISTEN-IN OPTIONS
OUTPUT # 1 LISTEN-IN OPTIONS -
P175E 7E
Option 1 - Listen-in Enabled when dialling only and in Disarmed State
Option 2 - Listen-in Enabled when dialling only and in Armed State
Option 3 - Listen-in Enabled when dialling only and in Monitor Mode
Option 4 - Listen-in Enabled through the entire call only in Disarmed state
Option 5 - Listen-in Enabled through the entire call only in Armed State
Option 6 - Listen-in Enabled through the entire call only in Monitor Mode
Option 7 - Listen-in Enabled when the panel answers a call
Option 8 - Listen-in on at All Times
The panel provides the facilities to use a speaker connected to Output # 1 to listen to the call being made by the dialler.
For this to happen the device connected to output # 1 must be an 8
Ώ
horn speaker. The options above allow many
combinations of the listen-in to be used or it can be disabled by selecting no options.
DIALLING PRE-FIX NUMBER
DIALLING PRE-FIX NUMBER -
P175E 8E (Value 1-16 digits)
The panel can be programmed with a Pre-fix telephone number. The Pre-fix number can be up 16 digits long. The Pre-fix
number can be dialled before any of the 8 Telephone numbers if required (P183E Option 7).
“PANIC” ALARM CONTACT ID REPORT CODE
“PANIC” ALARM CONTACT ID REPORT CODE -
P175E 9E (3 digit event code)
Normally a keypad initiated Panic alarm would default to reporting a standard “Panic Alarm” code of “120”. If the panic
alarm is being used for some other purpose and you need to identify the correct type of alarm event you can change the
event code at this location.
“FIRE” ALARM CONTACT ID REPORT CODE
“FIRE” ALARM CONTACT ID REPORT CODE -
P175E 10E (3 digit event code)
Normally a keypad initiated Fire alarm would default to reporting a standard “Fire Alarm” code of “110”. If the fire alarm is
being used for some other purpose and you need to identify the correct type of alarm event you can change the event
code at this location.
“MEDICAL” ALARM CONTACT ID REPORT CODE
“MEDICAL” ALARM CONTACT ID REPORT CODE -
P175E 11E (3 digit event code)
Normally a keypad initiated Medical alarm would default to reporting a standard “Medical Alarm” code of “100”. If the
Summary of Contents for Avolution S series
Page 119: ...119...