background image

FM361  04/20

Installation Instructions

Copyright © 2015, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole 

or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

For installation assistance contact Corbin Russwin 

1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com

 WARNING

This product can expose you to lead 
which is known to the state of California 
to cause cancer and birth defects or other 
reproductive harm. For more information 
go to www.P65warnings.ca.gov.

ED3400/ED3400A 

Series

Exit Devices

Surface Vertical Rod

Summary of Contents for Corbin Russwin ED3400 Series

Page 1: ...Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com WARNING This product can expose you to lea...

Page 2: ...ss Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com TOC Table of Contents 1 Tools Required 3 2 Package Content...

Page 3: ...s Required Measuring tape Power drill Drill bits 3 32 1 4 11 32 3 8 and 25 Taps 10 24 Screwdrivers Phillips 2 and Phillips 3 2 Package Contents This Exit Device Is Non Handed LHR Left Hand Reverse Hin...

Page 4: ...floor and draw horizontal line for active case template 3 Align template T31207 for active case with centerline and tape 4 Using crossbar hole centers for measuring draw vertical centerline of inactiv...

Page 5: ...is to door as indicated in Figure 5 and Figure 6 3 If installing a cylinder function ensure hub pin is in correct position Step 3c Note Active case is larger than inactive case Figure 7 Wood 10 x 1 1...

Page 6: ...igure 10 and Figure 11 Note Active case is larger than inactive case Figure 12 Wood 10 x 1 1 4 Phillips flat head Total 4 Metal 10 24 x 3 4 Phillips flat under cut Total 4 Inactive case mounting screw...

Page 7: ...template Note Use through bolt screws for fire rated doors 6 Ensure top latch bolt is fully extended 7 Rotate rod until upper hole see detail aligns with hole in active chassis and insert rod adjustm...

Page 8: ...ress crossbar arm to verify top latch goes into holdback 2 If latch does not go into holdback pull out the adjustment pin Rotate top rod counterclockwise one complete turn reinsert pin and test again...

Page 9: ...e and the following information For surface applied strikes 1 Transfer vertical centerline to floor or threshold and mark 2 Center strike on the marked line 3 Mark mounting holes If using Flush Bottom...

Page 10: ...Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com 3 Installation cont k Covers 1 Attach covers to both case chassis and...

Page 11: ...rews slightly 10 24 x 1 1 4 Phillips Oval Head Total 4 Rod Guide Mounting Screws Actual Size Rod Guide Mounting Screws Actual Size Wood 8 x 1 3 4 Phillips Oval Head Screw Total 4 Figure 27 m Crossbar...

Page 12: ...ights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russw...