ED5000N (S)(A) Series Exit Device
13
Copyright © 2018 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
8.
Attach Connectors (Interior PCB Assembly):
a. Connect P3 (2 Pin Connector) from trim to J3 on interior PCB
assembly (Fig 8).
b. Connect P4 (6 Pin Connector) from exit device to J4 on
interior PCB assembly.
c. Connect P5 (7 Pin Connector) from Reader PCB to J5
on interior PCB assembly.
d. Connect ElectroLynx®Harness (4 Pin & 8 Pin) from door
harness to ElectroLynx harness on Interior PCB Assembly.
e. Place extra wire inside door hole.
Note: Connectors go on only one way.
Do not offset connector and be sure they are
completely seated.
g R
From Reader
Board P5 to J5
From Lock
Body P3 to J3
From Lock
Body P4 to J4
ElectroLynx
Harness
J1
J2
Fig. 8
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock Neg
(Solenoid, neg)
3-Pink
-
1- Black
PWR NEG
3-White
DATA 1
5-Orange
RX (NO)
7-Brown
EGND
2-Gray Lock Pos
(Solenoid, pos)
4-Tan
-
2-Red
PWR POS
4-Green
DATA 0
6-Blue
RX (COM)
8-Yellow
LED
ElectroLynx
Door
Harness
P5
P4
P3
Ground Wire
Fig. 7
7) Installation Instructions (Continued)
Notes:
• Insert the ElectroLynx 8- and 4-pin
connectors and establish their
position inside the door prep.
• Neatly fold the wires onto
themselves and into the
remaining space to prevent
pinching wires when mounting escutcheon.
7.
Install Inside Escutcheon:
a. Make electrical connections (Step 8).
b. Feed excess ElectroLynx® wire harness back into door.
c. Feed excess trim and exit device under head cover.
d. Install inside escutcheon using (2) #8-32 x 5/8”
oval head screws.
Note: Be careful not to pinch wires between
escutcheon and door surface.