background image

Summary of Contents for Corbin Russwin ED5200N Series

Page 1: ...ion Instructions For ED5200N Series Exit Devices With 9600 TCRNE1 Series Trim M802 125 kHz Reader Option Includes Rim and SecureBolt FM294 10 18 Copyright 2018 Corbin Russwin Inc All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited For Technical Assistance call Corbin Russwin at 1 800 810 WIRE 9473 WARNING This product can ...

Page 2: ......

Page 3: ...ircuit different from that to which the receiver is connected Consult the dealer or an experienced technician for help The term IC before the radio certification number only signifies that Industry Canada technical specifications were met This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two condit...

Page 4: ... thicknesses upon request Consult factory Outside lever controlled by reader or key allows lever to retract latch Inside push bar produces REX request to exit signal and retracts latch Fail safe or fail secure operation must specify Wire from EAC panel to door must be shielded with a drain terminated at EAC panel controller Wires directly to EAC panels Accepts all HID 125 kHz bit formats McKinney ...

Page 5: ...One Way Length of Wire Run ft Load Current 12VDC 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1 000 10 1 500 10 Wire Gauge Charts Total One Way Length of Wire Run ft Load Current 24VDC 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 24 20 18 18 16 16 14 12 150 ...

Page 6: ...Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 Not Used 120 VAC Input 24 VDC H N G 24VDC Lock Body Power Power Supply By Others 12VDC DATA 1 DATA 0 RX RX Electrical Access Control Panel By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operation Black Hot White Neutral Green Gnd DPS DPS 12 Conductor Electro...

Page 7: ...Part Number Description Req 1 752F652 FIN Esc SA M802 Exits Rim CVR Functions 9603 9605 1 752F662 FIN Esc SA M802 Exits SVR LHR Functions 9S603 9S605 752F672 FIN Esc SA M802 Exits SVR RHR Functions 9S603 9S605 2 Exit Trim Refer to Access 600 Catalog to Configure Trim Order String 1 Refer to Access 600 Catalog to Configure Rail Order String Tools Required Phillips screw driver standard size Flat bl...

Page 8: ...rongs into matching notches of escutcheon 2 Pass cylinder tailpeice through cylinder collar if required and slot in cylinder cam 3 Fasten cylinder in escutcheon recess or collar using 2 mounting screws Do not overtighten screws d Escutcheon Assembly Fig 2b The lever is handed LHR shown Note Lever Return Spring is handed Hand cannot be changed without correct spring Lever Return Spring handing can ...

Page 9: ... wire harness through wire harness hole Fig 3a c Mount trim assembly to door pulling slack wire towards device side of door Note Be careful not to pinch wire harness d When mounting trim lift tailpiece to pass through hole on device side Note Make sure tailpiece is still oriented vertically e Fasten trim assembly to door using 2 1 4 20 oval head screws and 2 finish washers Fig 3b Note Finger tight...

Page 10: ... is prohibited 7 Installation Instructions Continued 4 Install Exit Device a Seat device against door being careful to align vertical trim tailpiece to engage with cross hole of device cam b Fasten device to trim assembly using 2 1 4 20 pan head screws c Follow instructions packed with device to secure device to door d Tighten all 4 screws Fig 4a Fig 4b Inside Face of Door Fig 4c ...

Page 11: ...s prohibited 7 Installation Instructions Continued 5 Install Head Cover a Lay wire harnesses trim harness and device harness across hole Fig 5a b Tuck wires into hole when installing cover so that wires are not pinched between head cover and door c Attach head cover using 2 8 32 flat head screws Fig 5b Use 3 4 hole to tuck trim and device wire harness under head cover Fig 5a Fig 5b ...

Page 12: ... Surface Vertical Rod sectoin on page 12 a Feed Reader wire harness through door and through hole in mounting plate Fig 6a b Insert two 8 x 1 3 4 flat head through mounting plate and into escutcheon Fig 6a and 6b c Connnect pin 5 green yellow ground wire ring terminal to top right screw Fig 6b and 6c Note Be careful not to pinch wires under mounting plate d Check that Reader is straight on door th...

Page 13: ...rom Lock Body P3 to J3 From Lock Body P4 to J4 ElectroLynx Harness J1 J2 Fig 8 PCB Layout Wire Assignments ElectroLynx Assembly Molex J2 J1 1 Violet Lock Neg Solenoid neg 3 Pink 1 Black PWR NEG 3 White DATA 1 5 Orange RX NO 7 Brown EGND 2 Gray Lock Pos Solenoid pos 4 Tan 2 Red PWR POS 4 Green DATA 0 6 Blue RX COM 8 Yellow LED ElectroLynx Door Harness P5 P4 P3 Ground Wire Fig 7 7 Installation Instr...

Page 14: ...face Vertical Rod installation follow the installation instructions on pages 4 8 before continuing a Position outside escutcheon against door Fig 4A Note Insert gasket if necessary b Route antenna cable through door c Route wires along the outside not through the mounting bracket Fig 4B d Secure with mounting bracket screws Fig 1 Ouside Escutcheon Gasket Mounting Bracket c a b d 2 Attach Ground Ri...

Page 15: ...y fold the wires onto themselves and into the remaining space along side the mounting bracket to prevent pinching wires when mounting escutcheon Connectors go on only one way Do not offset connector and be sure they are completely seated PCB Layout Wire Assignments ElectroLynx Assembly Molex J2 J1 1 Violet Lock DC Neg Solenoid neg 3 Pink NOT USED 1 Black PWR GND 3 White Wiegand DATA 1 5 Orange RX ...

Page 16: ...low the following step a Turn power ON at EAC panel b Verify LED located on reader is ON Red or Green depending on reader configuration See reader LED Configuration c Present proximity credential and verify LED and sounder activity d Verify valid card read at EAC Panel e Verify system operation functions i e when prox credential is presented to reader that the door unlocks Before closing door test...

Page 17: ...inte grity is validated at test unit X X Works with SE LP10 X X Displays detailed Wiegand data including hexadecimal string and total bits received X Displays measured end of line resistor values if applicable X The ASSA ABLOY Wiegand Test Unit verifies your installation in the field The test unit checks for proper wiring card reader data integrity lock functionality including lock unlock door pos...

Page 18: ...ED5000N S A Series Exit Device Notes 18 Copyright 2018 Corbin Russwin Inc All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited ...

Page 19: ......

Page 20: ...Fax 800 447 6714 corbinrusswin com Copyright 2018 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited Patent pending and or patent www assaabloydss com patents ...

Reviews: