5. Install Lock Body in Door:
Important: Door must remain open during installation. Use door stop.
a. Feed wires through 1-5/16” diameter hole on INSIDE of door while installing lock body (Fig. 5a).
b. Pull wires through hole while inserting lockbody. DO NOT push wires back into cylinder
hole (Fig. 5b).
c. Install, but do not tighten two #12 x 1” combination screws through lock body (Fig. 5a).
Fig. 5a
Fig. 5b
Outside Face
of Door
Inside Face
of Door
6. Install Inside Mounting Plate
a. Feed lockbody wires through mounting plate (Fig. 6a).
b. Place ground wire eyelet between lower left mounting
plate hole and flat head machine screw when
securing mounting plate to door (Fig. 6a).
c. Insert (2) #8 x 3/8” flat head screws
into pre-drilled
1/8” diameter holes (Fig. 6a).
Inside Face
of Door
Fig. 6a
Reader Backplate
Detail
The shorter 3/8” screw
must be used for Step 6c.
(2) #12 x 1”
Do not tighten
(2) 8-32 x 3/8”
Phillips Flat
Head Self- Drill-
ing Screw