7) Installation Instructions (Continued)
a. Feed excess ElectroLynx
®
and reader wires into door prep. Tuck excess body wire
harness under escutcheon.
b. Tighten the inside escutcheon securely to the mounting plate using the 8-32 x 5/8”
screw for the top of the escutcheon and the 8-32 x 1/4” screw for the bottom of
the escutcheon located under the turn lever (Fig, 12).
Be careful not to pinch wires
under escutcheon when tightening screws.
c. Be sure the turn assembly is functional and, if equipped with a deadbolt, that the
deadbolt functions properly.
Fig. 12
Inside Face of
Door
12. Install Inside Escutcheon: