26
SE LP10 ML20600 Mortise Lock
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For mortise locks with cylinders:
a. Insert key into cylinder and rotate: There should be no friction
against lock case, wire harness or any other obstructions.
b. The key will retract the latch: Key should rotate freely.
c. When the deadbolt is thrown: Ensure that the key retracts
both the deadbolt and the latch.
d. Inside lever: When used, ensure it retracts both the latch
and deadbolt (if provided).
e. Close door: Ensure latch and deadbolt fully extend
and do not bind.
8) Operational Check
Feature
WT1
WT2
12 or 24VDC solenoid lock
voltage adjustable
X
X
Operates as Fail Safe or Fail Secure
X
X
"Learn" mode allows testing of
specific cards without programming
at panel level
X
X
Card reader data integrity is vali-
dated at test unit
X
X
Displays detailed Wiegand data,
including hexadecimal string and
total bits received
X
Displays measured end-of-line
resistor values (if applicable)
X
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field*. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product’s features and capabilities.
Wiegand Test Unit
*For directions on use, see operating
instructions provided with unit.