Fitting and installation
Connecting an access control system in place of a key switch
Two independent inputs are available for connecting an access control system,
enabling one compact device to be connected for indoors and one for outdoors,
for example.
The connection takes place via the SYSCON 5 connection cable for the key switch
connection. The connections can be configured via the
ePED
®
Service Software
(instructions
D01104xx ePED
®
Service Software
).
The inputs switch the operating status via impulses. Resetting after alarms and
re-locking are both possible.
An optional permanent release is also available. For this, another impulse must be
initiated during a temporary release.
For correct function, the actuation time of the access control must be set to
around one second.
Fig. 40:
Connecting an
access control
system
5
4
3
2
1
S1
S2
S3
SYSCON 5
Function
1
red
–
2
black
GND
3
blue
S1 Connection 1 of
the access control
system
4
brown
S2 Connection 1 of
the access control
system
5
grey
S3 Sabotage contact