background image

8

800-810-WIRE (9473) • www.sargentlock.com • A7113E

1

2

/1

5

/0

7

©

S

A

R

G

E

N

T

M

a

n

u

fa

ct

u

ri

n

g

C

o

m

p

a

n

y

2

0

0

5

,

2

0

0

7

.

A

ll

ri

g

h

ts

re

se

rv

e

d

.

Keypad 10 Line Lock

8

/1

4

/0

8

C

o

p

yr

ig

h

t

©

2

0

0

5

,2

0

0

7

,2

0

0

8

,S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

,a

n

A

S

S

A

A

B

LO

Y

G

ro

u

p

c

o

m

p

a

n

y.

A

ll

ri

g

h

ts

re

se

rv

e

d

.

R

e

p

ro

d

u

c

ti

o

n

in

w

h

o

le

o

r

in

p

a

rt

w

it

h

o

u

t

th

e

e

xp

re

ss

w

ri

tt

e

n

p

e

rm

is

si

o

n

o

f

S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

is

p

ro

h

ib

it

e

d

.

Step #6 Securing the Lock to Door

1A. If wood door, feed wires up through

the routed channel as shown

1B. If metal door, feed wire connector within the

door core and out hole on inside of door

2.

Attach inside rose assembly and spacer
bushing and secure with screws shown

Step #7 Installation of Outside Escutcheon

• From the outside of the door,

feed keypad wires through fire
stop plate and to the inside of
the door. Lift plate cover if needed.

IMPORTANT – Fire stop
plate cover must lay flat
before installing the keypad
to avoid interference

Summary of Contents for KP10G77

Page 1: ...10 Line Lock KP10G77 A7113E 8 08 Copyright 2005 2007 2008 SARGENT Manufacturing an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited ...

Page 2: ... company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Table of Contents General Description 1 Specifications 1 Parts Breakdown 2 3 Features 4 Installation Instructions 5 12 Programming Instructions English 12 15 Chain Programming 16 Transaction Log 17 Guide De Progammation French 18 Page 1 2 3 4 5 6 7 8 ...

Page 3: ...ad with non volatile solid state memory The keypad will hold a total of 100 different User Codes User Codes 01 and 03 are utilized for Master Code and Supervisory Code respectively All programming is done at the keypad with over 1 100 000 possible user combinations This lock is operated by four 4 C batteries with a life span of approximately 50 000 cycles A portable infrared printer 52 2069 may be...

Page 4: ...65 73 65 73P lockbody 1 16 10 3049 Outside rose spring assembly not finished 1 17 10 0019 Cylinder spacer 1 17A 13 3613 Schlage SC cylinder provide keying details 1 17B 13 3614 Schlage SE cylinder provide keying details 1 17C 13 3713 Cylinder 10 Signature 1 18 10 0312 Cylinder retainer 1 18A 10 0313 Cylinder retainer for removable core 1 Interchangeable core Keso 19 13 3266 Cylinder standard provi...

Page 5: ...d 10 Line Lock 8 14 08 Copyright 2005 2007 2008 SARGENT Manufacturing an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited Parts Breakdown Continued ...

Page 6: ...standard codes passage codes or one time only codes All programming done at keypad Operates utilizing any two to six digits per code Digits may be repeated and codes may start with zero Minimum 40 000 cycles per set of batteries Cylinder override provided Entry of three wrong User Codes disables all codes for ten seconds Green LED flashes Piezo horn can be heard with each keystroke or turned off b...

Page 7: ...r according to appropriate template see website www sargentlock com For metal door template see 4486 and 4494 For wood door template see A7332 scale paper template ships with product and 4375 1 Prior to installation all holes must be free of burrs debris and sharp edges If doors are not properly reinforced per ANSI115 2 commercially available reinforcements should be installed Step 1 Verify Hand a...

Page 8: ...hibited Step 3 Frame Preparation for Strike Non Fire Rated Exterior Doors Install Weather Conduit P N 52 2847 as shown below Step 4 Latch and Fire Stop Plate Installation 1 Install latch with beveled bolt facing the strike 2 Attach with two screws but DO NOT tighten completely at this time 3 Attach Fire Stop Plate with two screws Note Required for all Fire Rated doors Important Latch bevel must ma...

Page 9: ...ove outside lever usually keyed scalp and spacer bushing Rotate mounting plate to either align with through bolt holes in door or adjust for proper door thicknesses see markings on through bolt Reinstall spacer bushing to align with back of lever scalp and lever Step 5 Lock Installation IMPORTANT Door must remain open during installation Use door stop 3 1 3 4 thick door 2 thick door Through bolt h...

Page 10: ...rohibited Step 6 Securing the Lock to Door 1A If wood door feed wires up through the routed channel as shown 1B If metal door feed wire connector within the door core and out hole on inside of door 2 Attach inside rose assembly and spacer bushing and secure with screws shown Step 7 Installation of Outside Escutcheon From the outside of the door feed keypad wires through fire stop plate and to the ...

Page 11: ...inside of the door use the 8 32 x 1 1 4 round head screw with the flat washer to attach the escutcheon thru the lower lug Straighten escutcheon and tighten the 8 32 round head screw Step 9 Installation of Inside Escutcheon Plug the smaller lockbody wires into the inside escutcheon Access holes vary based on wood or metal door application Plug keypad ribbon cable connector into inside escutcheon IM...

Page 12: ...ovided Carefully tuck the wire into the routed groove in wood door The remainder can fit within bottom portion of escutcheon Make certain that wires are not pinched by obstructions in escutcheon Place inside escutcheon flat against the door Secure inside escutcheon with one flat head screw thru interior of inside escutcheon and into post of exterior escutcheon Secure bottom of escutcheon with flat...

Page 13: ...thout the express written permission of SARGENT Manufacturing is prohibited Step 12 Battery Installation Place 4 C batteries into the compartment as indicated inside escutcheon Attach battery cover to inside escutcheon and secure with 8 32 x 3 8 security screw DO NOT OVER TIGHTEN How to Remove Outside Lever Only 1 Insert key rotate 45 clockwise and hold 2 Depress lever retainer with push pin tool ...

Page 14: ...pad Lock can support 100 users Each user is assigned a User Number in addition to the code used for entry 6 Example USER USER USER CODE TYPE NUMBER 2 6 DIGITS Master 01 1 2 3 4 Supervisor 03 3 0 3 0 3 0 Standard 04 97 2 6 5 Special Factory 98 10 Sec Time Preset 99 1 3 6 8 How to Change Cylinder if required 1 With outside lever in hand use standard pliers pull out cylinder retainer 2 Remove key and...

Page 15: ...uld not be required by other users To Begin Programming The Keypad 10 Line Lock is preset at the factory with Master Code 1234 Entering 1234 will unlock the lock allowing the lever handle to retract the latchbolt Initial Set Up Procedures The following are typical procedures to follow when setting up your KP10G77 Keypad If a mistake is made during any of procedures depress the several times until ...

Page 16: ...Begins to Blink Slowly 30 0 0 Yellow LED Continues to Blink Slowly Yellow LED Blinks Quickly No Beep on Depression and Yellow LED Blinks Slowly No Beep on Depression and Yellow LED Goes Out To Reactivate Beep With the Depression of Each Key Supervisory or Master Code Yellow LED Begins to Blink Slowly 30 0 1 Yellow LED Continues to Blink Slowly Yellow LED Blinks Quickly Beep on Depression and Yello...

Page 17: ...he actual entries Door 5666 Seq User Trans 1 001 003 2 003 001 3 003 001 4 020 001 5 003 001 Door Number Transaction Number User Number Transaction type To Reset Clear Transaction Log Supervisory or Master Code Yellow LED Begins to Blink Slowly 76 00000 00000 Yellow LED Blinks Slowly Yellow LED Begins to Blink Quickly Yellow LED Goes Out To Delete a User Number Master Code Yellow LED Begins to Bli...

Page 18: ...C_ UC_ An example with three user codes is shown below Type User Number User Code 1 07 77 1 15 67832 1 91 7568 Using Master Code 45988 and above information the lock would be programmed as follows 99 45988 50 1 07 77 77 15 67832 67832 91 7568 7568 To chain the User Number delete procedure 99 Master Code User Number a UNb UNc UN_ Using the information from the above example 99 45988 07 15 91 Chain ...

Page 19: ...gned by user Transaction Number Single digit 1 6 Latest transaction 1 Oldest transaction 6 User Number Three digits 001 through 099 User numbers assigned at time of programming Transaction Types 001 Access granted 003 Log printed Optional Equipment Printer Paper 6 Rolls 52 0034 used for infrared printers Auxiliary Power Unit APU 52 2065 used to unlock unit if batteries are too weak and cylinder is...

Page 20: ... de son code d entrée Example Type d usager Numéro d usager Code d usager 2 à 6 chiffres Maître 01 1 2 3 4 Urgence 02 2 2 2 2 2 Superviseur 03 3 0 3 0 3 0 Ordinaire 04 à 97 2 6 5 Spécial usine 98 10 secondes 99 1 3 6 8 Serrure à clavier KP10G77 99 codes d utilisateurs disponibles à la programmation Le code maître est toujours l utilisateur programmation Les utilisateurs sont Le code d urgence est ...

Page 21: ...perviseur suivi de Il continuera jusqu à l entrée du nouveau code suivi de Il clignotera ensuite rapidement jusqu à l entrée de Si le voyant reste allumé sans clignoter durant la programmation il y a eu une erreur de programmation et la séquence doit être recommancée Pour changer le code maître Entrer 99 1234 50 1 01 Nouveau code maître suivi de Nouveau code maître suivi de Pour entrer le code d u...

Page 22: ...fres suivi de Pour lire le rapport des activités Entrer 99 Code maître ou superviseur suivi de 70 0 0 Pour effacer le rapport des activités Entrer 99 Code maître suivi de 76 00000 00000 Remarque Après chaque programmation le voyant jaune devrait arrêter de clignoter S il clignote toujours après la dernière appuyer de nouveau sur Pour annuler un numéro d utilisateur Entrer 99 Code maître suivi de N...

Page 23: ...e 2 pour passage et 3 pour une fois UN_ est le numéro d utilisateur entre 04 et 99 UC_ est le code d utilisateur de 2 à 6 chiffres qui correspond au numéro d utilisateur 99 Code maître ou superviseur 50 Type Numéro d utilisateur a Code d utilisateur a Code d utilisateur a T Unb Ucb Ucb T Unc Ucc Ucc T UN_ UC_ UC_ Ceci est un exemple de quatre codes d utilisateurs Type Numéro d utilisateur Code d u...

Page 24: ...ra donc simplifié 99 Code maître ou superviseur 50 Type Numéro d utilisateur a Code d utilisateur a Code d utilisateur a Unb Ucb Ucb Unc Ucc Ucc UN_ UC_ UC_ Ceci est un exemple de trois codes d utilisateurs En utilisant le code maître 45988 et les renseignements ci dessus la programmation de la serrure sera la suivante 99 45988 50 1 07 77 77 15 67832 67832 91 7568 7568 Pour annuler en chaîne les n...

Page 25: ...umber Transaction type Transaction Log 7 To output the last 15 entries enter 99 Supervisory or Master Code 70 0 0 Door Number 4 Digits Up to 9999 different doors assigned by user Transaction Number Single digit 1 6 Latest transaction 1 Oldest transaction 6 User Number Three digits 001 through 099 User numbers assigned at time of programming Transaction Types 001 Access granted 003 Log printed Opti...

Page 26: ...customer base includes commercial construction institutional and industrial markets Copyright 2005 2007 2008 SARGENT Manufacturing an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security ...

Reviews: