Lock status monitor is not working:
Confirm correct wires are being used by testing with a multi-meter
• Signal should be open when the lock is unlocked and closed
when lock is locked
Lock status monitor state will only change when the lock is
powered (the lock will only change state when powered as well)
LED is not active:
Lock is supplied with LEDs de-activated. Refer to instructions on
how to activate the LEDs
Having the LED’s programmed as active can also assist in fault
finding the installation
LEDs turn off after 10 seconds:
The LEDs will turn off after 10 seconds when being powered in 2
wire mode (red and green wires joined)
• Wire lock in 3 wire configuration if continuous LED
operation is needed
LED shines red briefly and then green after
sending unlocking signal:
The LED indicates the status of the lock and will only change to
green once the lock has confirmed that it is definitely unlocked.
If the lock is being powered in 2 wire PtO – this will result in the
LED being off and then when a locking signal is received, the LED
will be red for a fraction of a second before changing to green once
unlocked.
• 2 wire PtO is not recommended
LED is not visible after fitting furniture:
4800 lens furniture requires an extra hole to be drilled above top
furniture mount hole – has this been drilled
• If yes, remove furniture and confirm LEDs are operating on
lock and inspect for obstructions